6.1.3
Metric Bolt Specifications Bolting into Cast Aluminum
Table 6.9 Metric Bolt Bolting into Cast Aluminum
Bolt Torque
8.8
(Cast Aluminum)
10.9
(Cast Aluminum)
Nominal
Size (A)
N·m
ft·lbf
N·m
ft·lbf
M3
–
–
–
1
M4
–
–
4
2.6
M5
–
–
8
5.5
M6
9
6
12
9
M8
20
14
28
20
M10
40
28
55
40
M12
70
52
100
73
M14
–
–
–
–
M16
–
–
–
–
Figure 6.9: Bolt Grades
6.1.4
Flare-Type Hydraulic Fittings
1.
Check flare (A) and flare seat (B) for defects that might
cause leakage.
2.
Align tube (C) with fitting (D) and thread nut (E) onto
fitting without lubrication until contact has been made
between flared surfaces.
3.
Torque fitting nut (E) to specified number of flats from
finger tight (FFFT) or to a given torque value in Table
6.10 Flare-Type Hydraulic Tube Fittings, page 75
.
4.
Use two wrenches to prevent fitting (D) from rotating.
Place one wrench on fitting body (D), and tighten
nut (E) with other wrench to torque shown.
5.
Assess final condition of connection.
Figure 6.10: Hydraulic Fitting
214048
74
Revision A
Summary of Contents for DWA
Page 6: ......
Page 18: ......
Page 48: ......
Page 60: ......
Page 62: ...REPAIR PARTS 5 1 Deck Draper and Rollers 214048 54 Revision A...
Page 64: ...REPAIR PARTS 214048 56 Revision A...
Page 66: ...REPAIR PARTS 214048 58 Revision A...
Page 68: ...REPAIR PARTS 5 2 Linkage and Deck Support 214048 60 Revision A...
Page 70: ...REPAIR PARTS 214048 62 Revision A...
Page 72: ...REPAIR PARTS 214048 64 Revision A...
Page 74: ...REPAIR PARTS 5 3 Decals and Reflectors 214048 66 Revision A...
Page 76: ......
Page 94: ......
Page 96: ......
Page 97: ......