Operational
Overview
AES16 User Manual
47
indicator in the SynchroLock status window is
observed. This status window is located on
the Adapter page of the Lynx Mixer.
SynchroLock works on any external word
clock signal. By default, SynchroLock is active
when the Sample Clock source is set to a
clock source other than Internal. When the
clock source is set to “External,” “Header,” or
“Lstream” the Reference must be set to
“Word.” SynchroLock can be disabled in the
settings menu of the mixer by clicking on
“Settings > Advanced > SynchroLock,” but
this is not recommended.
SynchroLock is capable of locking to word
clock frequencies /- 100ppm of 44.1
kHz, 48 kHz, 88.2kHz, 96 kHz, 176.4 kHz, or
192 kHz. Signals that fall outside of the lock
range will cause the red RANGE indictor to
appear in the SynchroLock status
window.