• Rotate dial B to the end time of the first comfort period,
then slide switch E to then back to to confirm.
• LED A will change from flashing green to flashing red.
• Rotate dial B to the start time of the second comfort
period, then slide switch E to then back to to confirm.
• LED A will change from flashing red to flashing green.
• Rotate dial B to the end time of the second comfort
period, then slide switch E to then back to to confirm.
• LED A will change from flashing green to flashing red.
• If more than two Comfort periods are required, repeat
the previous steps for the start and end time of each
comfort period.
• If all comfort periods have been defined for Day 1, rotate
dial B to hour 24, then slide switch E to then back to
to confirm.
• LED A will be off.
• LED C will start flashing orange/green, indicating that
dial D must now be set to Day 2.
• Rotate dial D to Day 2.
• Repeat the previous steps for setting all desired comfort
periods for Day 2 to Day 7.
Note:
If LED A was flashing green at the end of the
previous day (comfort), LED A will flash green at the start
of the following day, signifying that the comfort period
will continue into the following day. Rotate dial B to the
end of this comfort period, and switch E to then back
to to confirm. LED A will change from flashing green to
flashing red.
• When dial D is set to hour 24 on Day 7, signifying all
comfort periods have been defined, slide switch E to
then back to to confirm.
• The user defined program will be stored and the
thermostat will automatically exit, and return to the
parameter menu.
• LED A & C will flash green.
SELECT ADDITIONAL FEATURES
The thermostat has Adaptive Start and Open Window
Detection functions.
ADAPTIVE START
Disabled
- Heating up to reach the Comfort set
temperature will start at the programmed time.
Enabled
- Heating up will start at the predicted optimal
time to reach the Comfort set temperature at the
programmed time.
Note:
This feature will only function when the radiator
follows the built in programmer.
OPEN WINDOW DETECTION
This function will switch the radiator from any active
mode to “Frost Protection” mode when an open window
is detected (room temperature drops by more than 2°C in
less than 10 minutes). LED A will change to solid orange,
and flash red every 1 minute when heating, or flash green
every 1 minute when not heating.
To enter into this menu and select these additional
features, follow the below steps:-
YA
LI C
O
M
FO
RT I
N
ST
A
LL
AT
IO
N AN
D OPER
AT
ING M
A
N
U
A
L
201
8-
02
-01
YA
LI C
O
M
FO
RT I
N
ST
A
LL
AT
IO
N AN
D OPER
AT
ING M
A
N
U
A
L
201
8-
02
-01