GB
GENERAL
INFORMATION
1. GENERAL INFORMATION
• This appliance is a sealed electric radiator designed for
fixed wall-mounted installation.
• This appliance conforms to the standards EN 60335-1
and EN 60335-2-30.
• The appliance is insulation class I and has electrical
protection level IP21 if used with the standard connection
box, and electrical protection level IP44 if used with the
standard connection box AND the splash-proof cover (to
be ordered separately) or fitted with a 2-pin Schuko plug.
• This appliance complies with the European directive
2004/108/EC (CE marking on all appliances).
• The product is supplied with wall brackets and screws.
• The YALI C C is supplied complete with a connection cable
equipped with a 5-pole connector and connection box.
• The YALI C P (where available) is supplied complete with a
connection cable equipped with a 2-pin Schuko plug.
PLEASE NOTE:
The YALI C P has limited functionality due to only being
equipped with a 2-pin Schuko plug, therefore it will
not be possible to have a wired connection to a central
programmer, external clock, BMS, or to have the radiator
connected in a master/slave setup.
2. INSTALLATION
POSITIONING
• The radiator must be positioned horizontally in order
for it to function correctly.
• The radiator must be positioned according to the
applicable standards. The minimum distances as
specified in picture 1 should be carefully observed.
• The radiator may be positioned "outside" zone 2 with
the standard connection box and inside zone 2 if the
connection box is equipped with a splash-proof cover
(picture 2) insofar as no operating controls (buttons,
switches etc.) are in reach of persons in the bath or under
the shower.
• The radiator must be fixed to the wall using the wall
brackets supplied.
• The radiator must not be located underneath an
electrical socket.
FIXING
• Mark out the distance between the brackets and the
positions of the screw holes as shown in the table in
picture 3A (single panel) or 3B (double panel). Note that
2000 mm long products are supplied with extra brackets as
a 3rd bracket must be fitted in the middle of the product.
• Note that the brackets can be used to measure the height
of the bottom fixing hole, see picture 3C.
• For the correct installation of radiators it is essential that
the fixing of the radiator is carried out in such a way that it
is suitable for intended use AND predictable misuse.
A number of elements need to be taken into consideration
including the fixing method used to secure the radiator
to the wall, the type and condition of the wall itself,
and any additional potential forces, or weights, prior to
finalising installation.
• The fixing materials provided are only intended for
installation on walls made of solid wood, bricks, concrete
or on timber-frame stud walls where the fixing is directly
into the timber. All walls being considered should have no
more than a maximum of 3 mm wall finishing. For walls
made of other materials, for example hollow bricks;
please consult your installer and/or specialist supplier.
In all cases it is strongly recommended that a suitably
qualified professional installer or similar tradesperson
carries out the installation.
CONNECTION
• The electrical installation must comply with local or
national regulations.
• The radiator should be connected by a suitable and
qualified electrician. Please refer to the wiring diagram
in picture 4A for the connection of the radiator. (Excludes
YALI C P model).
• The radiator must be connected to the electrical supply
using the supply cable fitted to the unit.
• If the radiator is installed in a bathroom or shower room
it must be protected with a residual current device (RCD)
with a rated residual current not exceeding 30 mA.
• The radiator is equipped with a non-resettable overheat
protection that trips off if the radiator overheats. If the
radiator is removed from the wall brackets, even for a
short time, it must without exception be switched off, see
picture 4B. This may even trip the non-resettable overheat
protection. If the overheat protection trips, its thermal fuse
must be replaced; contact your supplier.
YA
LI C
O
M
FO
RT I
N
ST
A
LL
AT
IO
N AN
D OPER
AT
ING M
A
N
U
A
L
201
8-
02
-01
YA
LI C
O
M
FO
RT I
N
ST
A
LL
AT
IO
N AN
D OPER
AT
ING M
A
N
U
A
L
201
8-
02
-01
77