GB
GENERAL
INFORMATION
84
• Rotate dial D to
-5
then slide switch E to then back to .
• LED A will stop flashing green and change to solid
orange.
Orange = feature not selected.
Green = feature currently selected.
• LED C will be off.
Note:
Adaptive Start and Open Window Detection are
both set to enabled by default.
Symbol Adaptive Start Window Open Detection
Disabled
Disabled
Disabled
Enabled
Enabled
Disabled
-3,5
Enabled
Enabled
-5
No function
-10
No function
-15
No function
S
Exit (return to top level of parameter menu)
• Rotate dial D to
or
-3,5
and then slide switch E
to then back to to confirm.
• LED A will change to solid green to indicate the currently
selected option.
SELECT PROGRAMS
The thermostat has 6 preset heating programs, P1 – P6
(picture 6) and 1 user defined heating program, U1. To
enter into this menu and select one of these heating
programs, follow the below steps:-
• Rotate dial D to
-10
then slide switch E to then back to
to confirm.
• LED A will stop flashing green and change to solid
orange or solid green.
Orange = program not selected.
Green = program currently selected.
• LED C will be off.
Symbol
Program Number
P1
P2
P3
-3,5
P4
-5
P5
-10
P6
-15
U1
S
Exit (return to top level of parameter menu)
• Rotate dial D to the symbol relating to the desired
program, and then slide switch E to then back to
to confirm.
• LED A will change to solid green to indicate that this
program is now selected.
5. MAINTENANCE, REPAIR
AND DISPOSAL
•
WARNING:
Disconnect electrical supply before carrying
out any maintenance activity.
• The product should be cleaned using a soft damp cloth.
Do NOT use chemical or abrasive cleaners as they will
damage the surface finish.
• The radiator is equipped with overheat protection that
cannot be reset (melt fuse). This overheat protection
disconnects the current if the radiator becomes too hot
(e.g. when covered).
• If the supply cord is damaged, it must be replaced by the
manufacturer, a service agent or similar qualified persons
in order to avoid a hazard.
• The radiator is filled with an exact amount of
environmental friendly vegetable oil. Any repairs that
require the radiator to be opened shall therefore only be
carried out by the manufacturer or an approved agent.
• In case of leakage contact the manufacturer or service
agent.
• When the radiator reaches the end of its service life
follow the regulations concerning the disposal of oil.
YA
LI C
O
M
FO
RT I
N
ST
A
LL
AT
IO
N AN
D OPER
AT
ING M
A
N
U
A
L
201
8-
02