DC power
Interlocks
User shutter enable
Shutter position
RF enable
Laser enable
Output power
AOM demand
0
100ms
200ms
300ms
400ms
Figure 25 - Startup timing — Interlocks and RF pre-enabled
Table 19 - Parameter settling times
Parameter
Description
Previous required input
Minimum
settling time
DC
SETTLE
Minimum time for soft-start of the DC power
supply.
None
80ms
INT
SETTLE
Minimum time for the
Interlock
signal to
propagate through the system.
None
20ms
SHTR
SETTLE
Minimum time for the shutter to open after
applying the
User shutter enable
signal.
•
DC power
•
Interlocks
80ms
RF
SETTLE
Minimum time for the
RF enable
signal to
propagate through the system.
None
20ms
MOD
SETTLE
Minimum time between applying the
Laser
enable
signal and achieving stable laser
output into the AOM module.
•
DC power
•
Interlocks
•
User shutter
enable
•
RF enable
200ms
The dual channel safety critical approach [EN:13849 Performance Level D] requires the system to react
to system conditions as follows:
• When the external
Interlock
is disabled,
User shutter enable
and
RF enable
must
also be disabled by the machine controller.
• When restarting the system with the external
Interlock
enabled, the control signal startup
timing sequence must be followed.
8.5. Status indicators
The operational status of the laser is displayed by status indicator lamps on the laser rear panel.
8. Interfacing
42
906-0227-00 REV 1