Table 6 - Coolant specification — laser
Model
SR 10 AOM
SR 25 AOM
Minimum flow rate (L/min)
4
5
Recommended flow rate (L/min)
≥ 6
≥ 6
Maximum pressure
6bar
Dissipation
3kW
5kW
Required refrigeration capacity
> 3kW
> 5kW
Coolant temperature (laser)
18–25°C ± 1°C (above dew point)
Refer to document 906-0202-99 for more details.
Table 7 - Coolant specification — AOM module
Model
SR 10 AOM
SR 25 AOM
Minimum flow rate (L/min)
2
2
Recommended flow rate (L/min)
≥ 3
≥ 3
Maximum pressure
3bar
Dissipation
0.45kW
0.5kW
Required refrigeration capacity
> 0.45kW
0.5kW
Coolant temperature (AOM)
18–20°C ± 1°C (above dew point)
2.3.5. Optics purge gas
Table 8 - Optics purge gas specification
Purge gas pressure
0.07–0.21bar (1–3psi)
Flow rate
1–2L/min
Nitrogen purity
Nitrogen purity grade
≥ 4.6 (O
2
≤ 3vppm, H
2
O ≤ 2vppm )
Compressed air contamination limits
Oil
≤ 0.005mg/m
3
Water
≤ 0.05g/m
3
Particles
≤ 0.05µm
2.3.6. Environmental specifications
Note: This equipment is designed for indoor use only and Pollution Degree 2 as defined within EN
61010-1:2010+A1:2019
Table 9 - Environmental specifications
Ambient working temperature
5–30°C
Storage temperature (with drained cooling circuit)
-10 to +30°C
Relative humidity (non-condensing)
10–85%
Maximum altitude
< 2000m
906-0227-00 REV 1
13
2. General Description
Summary of Contents for SR 10 AOM
Page 1: ...USER MANUAL SR AOM series Sealed CO2 laser sources with integrated AOM...
Page 8: ...Preface iv 906 0227 00 REV 1...
Page 40: ...6 Installation 32 906 0227 00 REV 1...
Page 42: ...7 Transport and recommissioning 34 906 0227 00 REV 1...
Page 52: ...8 Interfacing 44 906 0227 00 REV 1...