4
The voice dialler will call each active number in the dialling sequence in turn. When a call is answered
the pre-recorded alarm message will be replayed. If the call is unanswered or an acknowledgement
signal is not received from the number called, (i.e. by pressing the button on the telephone keypad)
the next number in the sequence will be called.
Press
ESC
!
to exit voice dialler test.
Factory Defaults
Item
Defaut
User Access Code
134
Alarm Duration
3 minutes
Hardwired Siren
Equal to Alarm Duration
Zone Operating Mode
Zones 1-6: Intruder
Part-Arm
Zones 1: Disabled
Zones ,3,4,5,6: Active
Instant/Delay
Zone 1: Delay
Zones -6: Instant
Entry/Exit Delay
30s
Entry/Exit Warning Tone
On
Zone Lockout
On
Jamming Detection
On
Phone Numbers
Not programmed
Message Play Time
70s
Alarm Message
Not programmed
Call Routing
All numbers disabled
Call Attempts
3
Dial Method
Tone/DTMF
Reset Factory Default Conditions
1. Press
,
?
?
?
?
,
User Access Code
to place the system in Test Mode.
. Undo the Control Panel cover fixing screws and open the cover.
3. Switch OFF the mains supply to the plug-in PSU Adaptor.
4. Remove either back-up battery and disconnect the battery leads.
5. Set jumper link P1 to the ON position.
6. Reconnect the battery leads and replace the back- up battery in position.
7. The Control Panel will now set itself with all factory default settings. This takes approx. 10 seconds.
8. Reconnect and switch On the supply to the PSU adaptor.
9. Reset jumper link P1 into the OFF position.
10. Close the Control Panel cover and refit the fixing screws.