Setting the Solar Siren
Ensure that the Solar Siren main configuration switch if fitted on the LED strobe board is set to
“SIREN” for use with this alarm system.
Undo the 3 screws holding the DIP Switch cover in place and remove the cover.
House Code
Under the corner cover you will find a series of 9 DIP
switches. DIP switches 1- 8 are used to set the House Code
for the siren and must be set to the same ON/OFF
combination as all other system devices.
Note: When the Solar Siren is viewed as shown above
(Solar panel at top) the DIP switches are ‘upside down’.
Alarm Duration Limit
If required the maximum length of time that the External Solar Siren will sound for when activated
under an alarm condition may be limited to 3 minutes using DIP switch 9 as follows:
OFF 3 minute limit
ON 10 minutes or same as programmed setting on Control Panel.
Beep Disable
The Solar Siren will acknowledge Disarm signals from the Remote Control by beeping twice. It is
possible to disable the beeps if required by removing the jumper link P on the circuit board.
Siren Disable
If for any reason you need to disable the Siren, remove jumper link P3 on the circuit board. This
will prevent the Siren from sounding during an alarm condition. However, the Siren will still beep to
acknowledge signals from the Remote Control, (provided the beep feature is not disabled).
Once you have completed configuring the Solar Siren, refit the DIP switch cover and replace the
three cover fixing screws. Do not over tighten the screw as this could damage the thread.
Initial Power-Up of the Solar Siren
1. Connect the 9V PP3 initial power battery to the battery clip.
Connect the rechargeable battery to the charging leads. Connect the Red lead to the Red (+)
terminal and the Black lead to the Black (-) terminals.
Note:
Once the batteries have been connected, the Siren will be operational and it is important
that the Solar panel receives sufficient light to maintain the battery charge. The Siren should not
be operated repeatedly during installation and testing, as this will rapidly drain the battery. It is
recommended that the Siren be left for at least a day in order to charge the battery before the
system is armed.
Alarm Duration DIP switch 9