![Lütze LION Series Operating Instructions Manual Download Page 58](http://html1.mh-extra.com/html/lutze/lion-series/lion-series_operating-instructions-manual_1951222058.webp)
LION I/O Modules
▪
Digital Outputs, SIL0
58
9.4.4
Process Data Image
9.4.4.1
Input Data
Diagnosis Data
Data Structure
Fig. 59: Diagnosis Data Structure – Input Data RO8
9.4.4.2
Output Data
Output Data
Processdata per relay
–
Diagnosis data
per relay
Switching cycle counter
[3 Bit per relay]
Total
3 Byte
Switching cycles
Binary Value
0
000 (initial value ex-works)
10,000
001
50,000
010
100,000
011
250,000
100
500,000
101
750,000
110
1,000,000
111
Bit
Relay
Content
0, 1, 2
1
Binary value of switching cycles
3, 4, 5
2
Binary value of switching cycles
6, 7, 8
3
Binary value of switching cycles
9, 10, 11
4
Binary value of switching cycles
12, 13, 14
5
Binary value of switching cycles
15, 16, 17
6
Binary value of switching cycles
18, 19, 20
7
Binary value of switching cycles
21, 22, 23
8
Binary value of switching cycles
Rela
is
8
Rela
is
7
Rela
is
6
Rela
is
5
Rela
is
4
Rela
is
3
Rela
is
3
Rela
is
2
Rela
is
1
2
3
22 2
1
20
19 18 17 16 15 14 13 1
2
11 1
0
9
8
7
6
5
4
3
2
1
0
Output Data
Processdata per relay
Relay status [1 Bit per relay]
Diagnosis data
–
Total
1 Byte