Digital I/O Modules
▪
Digital Outputs
58
11.5.4
Connecting the Digital Outputs
Connect the digital Outputs in 3 groups via the two cage clamps X1 and X2.
Follow these steps:
Coding
1. Switch off the power.
2. Connect the outputs regarding the
pin assignment and the signals.
Digital Outputs 110 V
(redundancy capable) Diagnosis
Cage Clamp X1 and X2
Pin
Signal
Description
1
US
A
DC 110 V - Potential A
2
DO 1
Output 1
3
DO 2
Output 2
4
US
B
110 V DC - Potential B
5
DO 3
Output 3
6
DO 4
Output 4
7
US
C
110 V DC - Potential C
8
DO 5
Output 5
9
DO 6
Output 6
10
PE
Protective Earth
Module
Plug
Connectors
Cage
Clamp
110 V
Pin 1 and 10
Pin 2, 3, 4
and 7
110 V
red.
Pin 1 and 10
Pin 2, 3, 4
and 7
It is not necessary to connect cage clamp X1 and X2.
Pin 1 on X1 is bridged
with Pin 1 on X2. It is only for simplify thewiring of the vehicle.
Summary of Contents for 746400
Page 1: ...Operation Instructions DIOLINE20 Digital I O Modules Version 4 50...
Page 30: ...Digital I O Modules Digital Inputs 26 10 2 5 2 Block Diagram 2x8 Digital Inputs 72 V...
Page 31: ...Digital I O Modules Digital Inputs 27 10 2 5 3 Block Diagram 2x8 Digital Inputs 110 V...
Page 39: ...Digital I O Modules Digital Inputs 35 10 3 5 2 Block Diagram 4x4 Digital Inputs 72 V...
Page 80: ...Digital I O Modules Relay Outputs 76 13 3 5 Operation 13 3 5 1 Block Diagram Relay Outputs...
Page 81: ...77 14 Spacer 14 1 Characteristics Spacer for project planning Does not have any cage clamps...
Page 89: ...by L tze Transportation GmbH Weinstadt Germany Technical changes reserved...