background image

The following credits are available for this manual:

 

ƒ

Art-Net™ Designed by and Copyright Artistic Licence Holdings Ltd.

 

ƒ

ANSI E1.20 - 2010 Entertainment Technology RDM, Remote Device Management over DMX512 Networks.

 

ƒ

ANSI E1.31 - 2018 Entertainment Technology - Lightweight streaming protocol for transport of DMX512 

using ACN.

 

ƒ

BlackTrax by Cast Software

39

8. Credits

Summary of Contents for LumiCore

Page 1: ...USER MANUAL LUMICORE PRODUCT FAMILY LumiCore THANKS FOR CHOOSING LUMINEX Description User Manual LumiCore REVISION 20220629 REV 2 4 1...

Page 2: ...ABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONEL AVERTISSEMENT AUCUNE PI CE CONTENUE L INT RIEUR NE PEUT ETRE R PAR E PAR L UTILISATEUR VEUILLEZ CONFIER TOUTE R PARATION UN PERSONNEL QU...

Page 3: ...pment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If you wish t...

Page 4: ...eset via LumiNet Monitor 11 Reset via Araneo 11 3 CONFIGURATION 12 Web interface Presentation 12 3 1 Node Page 12 How to reset a process engine 13 How to configure a process engine 13 How to copy a pr...

Page 5: ...24 5 WEB API 26 6 LUMICORE IN DETAIL 27 6 1 What is a process engine 27 input 28 Output 30 Mode Definition 32 patch option 35 Patch Import Export 35 Master Limit option 35 master limit explained 36 st...

Page 6: ...1 Control room 2 Fixtures A few examples of applications where the LumiCore can be used Touring Live events Studio s Cruise ships Yachts Theatres Arena Stadium lighting Architainment lighting Theme pa...

Page 7: ...o mount two LumiCore devices or a LumiCore and a LumiCore4 in a standard 19 inch rack you can mount the two devices together A space saving way as the two devices will only consume a single row in you...

Page 8: ...ear of the device Use the correct bold M10x20 socket headcap screw with a screw wire no longer than 20 mm You can order this part from Luminex Part Number R 90 01042 Screw the bolt through the LumiCor...

Page 9: ...PoE injector All models can only be powered with PoE via ETH2 If both AC power and PoE are used the AC power supply will be prioritised but the PoE will seamlessly take over if the AC power fails 2 3...

Page 10: ...LAN 2 4 LED indicators There are various LEDs on the LumiCore Here is a list of the LEDs the possible colours and the meaning of each colour 2 5 Connection to the web interface The LumiCore IP address...

Page 11: ...LUMINET MONITOR LumiNet Monitor is available for Windows and MacOS and can be found in the download section of our website http www luminex be support 2 product downloads How to reset your LumiCore th...

Page 12: ...ons The colour of the icon will change if any parameters of these menus are modified For more details about the process engines and how to configure them please see chapter 6 of this manual F Output T...

Page 13: ...modes or combination of on a channel level At any time you can click on the Patch button the Master Limit button or the Startup Buffer button to open the relevant configuration panel Next click on th...

Page 14: ...e a complete configuration in a snap 3 2 Play page The play page is divided in two sub menus SHOW Here you select in which show you want to record cues which cue number and the fade time in seconds Ot...

Page 15: ...s 0 0 0 0 is used all devices in the network generating the assigned control protocol and universe can be the control source The LumiCore will use an LTP merging policy between the first four sources...

Page 16: ...uestion mark symbol on the Global Settings page Contact Closure General x Do Nothing 0 7 Switch x 8 15 Input 1 x 16 23 Input 2 x 24 31 Input 3 x 32 39 Input 4 Play x 8 15 Go x 16 23 Forward x 24 31 Ba...

Page 17: ...ess if required Click Save N to apply the changes Enter the new IP address in your web browser to refresh the page SCENARIO 2 B ADVANCED Groups VLANs including an ISL group Trunk can be assigned to po...

Page 18: ...roup Trunks window F select the group for the system interface you wish to use With the group selected click the group assignment on the system interface J Network ports Depending on the configuration...

Page 19: ...not be able to reach the web UI on this IP address In the Group Trunks window F select the group for the lighting data you wish to use With the group selected click the group assignment on the input i...

Page 20: ...o assign in the Group Trunks window F With the group selected click the Ethernet port you wish to assign to this group Repeat these steps for the second Ethernet port if required In the image on the p...

Page 21: ...to add a trunk Give the new trunk a name in the name field Assign a colour to the trunk by clicking on the coloured square After selecting the colour click anywhere outside the colour picker window to...

Page 22: ...ant to load the IP settings saved in the profile slide the Preserve IP settings to OFF FIRMWARE In the firmware section you can see two versions of firmware Active firmware is the one currently runnin...

Page 23: ...estored to factory default apart from the IP address set to reach the device Custom profiles are all deleted and modified default profiles are restored to default Preserve profiles during the reset th...

Page 24: ...ced networking is configured the LCD display will not be showing the IP configuration C Process engine number D Shows the mode of the process engine For a more detailed view per process engine you can...

Page 25: ...the unit Menu tree view Home Process Engines x Status overview of the process engines Setup Process Engine x Configuration of process engines Setup Network x IP x Subnet x Gateway x Mac address Profil...

Page 26: ...API The LumiCore range supports the use of Web API For a detailed list of available actions via Web API please type the following in your favourite web browser http IP_OF_YOUR_DEVICE api doc 26 5 Web...

Page 27: ...for more processing power and data handling flexibility This is where the LumiCore series steps in Instead of assigning universes to a port the user can now select any incoming data handle it the way...

Page 28: ...ces in the network By default the Accept Own Data is enabled sACN Any sACN controller can be used as an input for the process engine Tick the box to select sACN as an input protocol Here you can add t...

Page 29: ...he Source IP field you find a cog wheel for advanced settings Accept Own Data In some cases it is required to ignore the KiNET data generated by the LumiCore itself When disabled the LumiCore will onl...

Page 30: ...ay source Select the control channel you want to use to control the cue list Use the cog wheel to set the source protocol and universe and if required a specific controller IP Control channel options...

Page 31: ...etter identification you can add a text to your sACN destination KiNET All data handled by the process engine can be sent back to the network as a new or the same KiNET universe Here you can set the v...

Page 32: ...lay where the first input has precedence over the second input The output can be Art Net sACN KiNET or any combination of the three When input 1 fails the node will switch to input 2 automatically Aut...

Page 33: ...and startup buffer options are available for this mode SWITCH The switch functionality provides you with an easy to use tool to remotely select within up to four inputs which input can control your ri...

Page 34: ...1 only Input 2 only Input 3 only Input 4 only LTP HTP X Fade Backup and switch To get access to the custom patch panel click on the patch icon From this panel you can define the complete patch per inp...

Page 35: ...e This can be an easy way to start a custom patch to have the correct format for the patch file that you want to import at a later stage with your custom data Once you have the exported file you can c...

Page 36: ...nnel Master value x Channel value 255 For example Channel 1 200 Channel 2 229 Channel 3 128 If we now reduce the master channel to 204 the channels will output as follows Channel 1 160 Channel 2 183 C...

Page 37: ...This allows the user to configure values for each channel to be outputted from the LumiCore on bootup until the input source has been detected As soon as the first frame from the input source is pres...

Page 38: ...vailable online that gets updated on a regular basis at https support luminex be If you need to ask our team for more help or you need to return a device to Luminex for diagnostics or repair you can a...

Page 39: ...Copyright Artistic Licence Holdings Ltd ANSI E1 20 2010 Entertainment Technology RDM Remote Device Management over DMX512 Networks ANSI E1 31 2018 Entertainment Technology Lightweight streaming protoc...

Page 40: ...10 100 1000Mbps Port sensing Auto negotiation MDI MDIX Split management interface Yes Groups VLAN support Yes ADDITIONAL FEATURES Process Engine 64 Merging Yes HTP LTP Xfade Backup Switch Custom Softp...

Page 41: ...Dimensions W x D x H 220 x 175 3 x 44mm Weight 1 42kg Mounting type Rack mount Truss mount Packaging 420 x 272 x 80mm APPROVALS Electromagnetic emmisions and immunity EN55032 class A EN55035 EN61000 3...

Page 42: ...entation may be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording without the prior written permission of Luminex The information in t...

Page 43: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING...

Page 44: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex be...