RECORD TRIGGER
When you scroll down on the play page you will find the Record Trigger settings.
Here you can set the record channel, this is the channel you will be sending from your control device, the
control source protocol and universe. This can also be assigned to a specific source IP address if required.
The following options with corresponding values are available for the record trigger:
101 - record next cue in show 1
102 - record next cue in show 2
103 - record next cue in show 3
-
-
139 - record next cue in show 39
140 - record next cue in show 40
3.3 Global settings
The global settings page is divided in five sub menus:
CONTROL SOURCE
Here, you can set the type of protocol, the universe number, and the controller IP address for each control
source. If the IP address 0.0.0.0 is used all devices in the network generating the assigned control protocol
and universe can be the control source. The LumiCore will use an LTP merging policy between the first four
sources that become available. When using sACN the priority is also important to consider.
Each control source can be a different protocol, universe, and controller IP.
Press
Save
to apply your settings.
DEVICE SETTINGS
In this menu, you can set:
Short name. Enter a name of maximum 17 characters to indicate the core on Art-Net. The following
characters cannot be used: ^[ -~]*$.
Long name. Enter a name of maximum 63 characters to indicate the core on Art-Net. The following
characters cannot be used: ^[ -~]*$.
ID number of the LumiCore. The ID number is used for indication only.
Press
Save
to apply your settings.
DEVICE INFO
The device info window shows the MAC address and serial number of your device.
CONTACT CLOSURE
In this menu you can setup the details for the contact closure.
3 | ConfIGUratIon
15