100
TT
Command - Time Recall & Format Layout
Description
Use this com mand to define the time for mat and
print time data. The
TT
vari able is in serted
within a Text or Bar Code com mand's
DATA
parameter to print the time.
This com mand works only in print ers equipped with
the Real Time Clock (RTC) time and date op tion.
Syntax
TTp
1
[|p
2
|p
3
][+]
Parameters
P
1
,
P
2
,
P
3
=
h, m,
or
s
These pa ram e ters de scribe the for mat of
the time dis play.
•
At lease one pa rameter must be sup plied.
•
Each parameter can be any of the values
h
,
m
, or
s
and are described below.
Value
De scrip tion
h
Hours displayed as 2 digits (e.g. 01)
m
Minutes displayed as 2 digits (e.g. 15)
s
Seconds displayed as 2 digits (e.g. 00)
[+]
= En able 12 Hour clock for mat
Appending a + to the end of the com -
mand string selects 12 hour clock mode.
The times will dis play with an “AM” or
“PM” in di ca tor.
De fault
(no
+
) =
24
hour clock mode
|
= Sep a ra tor char ac ter
The sep arator may be any ASCII char -
acter value be tween 032 and 063. The
sep a ra tor char ac ter is printed be tween
the re sults of each of the sup plied pa -
ram e ters.
Power-Up De fault For mat
-
h:m:s
Examples:
If the cur rent time is 1:25 p.m.:
TTh:m:s+
�
: 01:25:00
TTh,m
�
: 13,25
TTh+
�
: 01 PM
3-100
980352-001 Rev.D
Summary of Contents for LK-B10
Page 2: ......