Rack adapter kit
....................................................................................................................................................................................................................................
Overview
The rack adapter kit is used to mount rack frames together
side-by-side to establish a line-up.
Before you begin
If the existing rack(s) already have side-cover plates, remove these
cover plates from the sides of the existing rack(s) to which another
rack(s) will be connected. See
for
instructions on how to re-install side-cover plates.
Installation procedure
............................................................................................................................................................
1
Extension side of the
existing rack is
Then
At the front to the left
Demount the rack adapter-kit on the
extension rack.
At the front to the right
Demount the rack adapter-kit on the
existing rack.
............................................................................................................................................................
2
Remove the Assy, Cage Nut — DC1002834 on the opposite side to
the demounted rack adapter-kit (see Step 1) (two at the top and the
two at the bottom).
............................................................................................................................................................
3
Place the rack frame (item 4) of the extension rack next to the
existing rack.
............................................................................................................................................................
4
Put the bushings (= spacers) for adapter kit — CC848316279 (item 1)
in the rack frame and fix them by using CH SCR, STL ST-70, M4x25
screws — CC847117900 (item 2) and STL, ST-70-140HV, 4.3x12
washers — CC847174950 (item 3) at each nut retainer-position.
............................................................................................................................................................
5
Tighten the CH SCR, STL ST-70, M4x25 screws — CC847117900
(item 2) to tie the rack frames together.
ETSI-2 installation
Mechanical installation
....................................................................................................................................................................................................................................
3 - 1 6
Lucent Technologies
365-374-074
Issue a, April 2002
E
N D
O F
S
T E P S
............................................................................................................................................................