6
Enable the DCC termination by selecting the
Enabled
option in the
DCC Channel Parameters
group box.
............................................................................................................................................................
7
Select
AITS
as
LAPD Mode
.
............................................................................................................................................................
8
Select the
LAPD Role
.
Important! This selection is not relevant for connections between
UNITE NEs. For interworking with not-UNITE NEs the chosen
parameters have to be different at both ends of the DCC termination.
That means at the one end must be set
USER-SIDE
, on the other end
NETWORK-SIDE
.
............................................................................................................................................................
9
Repeat
to
for all ports to which fiber cables are
connected.
............................................................................................................................................................
10
Repeat
to
for all other NEs in the ring/network.
SONET test procedures
Provision DCC
Span / Ring testing
....................................................................................................................................................................................................................................
8 - 3 0
Lucent Technologies
365-374-074
Issue a, April 2002