[Table 4.2.1.7] Description of each item of Error occurring Receiving Frame
No.
Items
Description
1
Start Byte
Byte indicating the start of Receiving Frame (displayed as F0)
2
Station ID
Station no. given to Reader (which adjusts the value of rotary
switch next to Reader)
3
Data Length
Total length of Frame (from Start Byte to Check Sum)
4
Control Mode
Mode to select the control environment of Reader
5
Error Code 1
Communication error between Reader and Host
6
Error Code 2
Tag Error Response message
7
Check Sum
Check Sum value
[Table 4.2.1.8] Error Code Classification (Error Response Table : Refer to Appendix B)
Items
Description
Error Code 1
Communication error table between Reader and Host
Error Code 2
Tag Error Response Message Table
In case of normal communication, the 5
th
Byte value of Receiving Frame returns “00”. But if
the value except “00” is received, error occurs. For other detailed information, please refer to
“Error Response Table (Appendix B)”.