![Lowara TDB 120 Installation And Operating Instructions Manual Download Page 57](http://html1.mh-extra.com/html/lowara/tdb-120/tdb-120_installation-and-operating-instructions-manual_1942518057.webp)
Installation, Operating and Maintenance Instruction
Model TDB, TDV
TDB, TDV
page 57
Revision 01
Issue 06/2012
Fy ...Force in direction of the y-axis
(perpendicular to the x-axis)
Fz ...Force in direction of the z-axis
(perpendicular to the x-axis)
Mx ...Torque around the x-axis
My ...Torque around the y-axis
Mz ...Torque around the z-axis
The suction and pressure joints must be considered
separately.
If not all loads in effect reach the value limits, one of
these loads may exceed the usual value limit by 1.4
times. The following requirement must be observed
here:
∑
∑
∑
∑
≤
+
2
)
)
/
(
)
/
((
2
.
.
max
2
.
.
max
zul
berechnet
zul
berechnet
M
M
F
F
TDB, TDV design
Permissible Forces / Torques on the DND Pressure
Joints
Dimension
Pressure Joints and
Suction Joints in
Line
Pressure Joints
Perpendicular to
Suction Joints
TDB 22
TDB 35
DND 40
Fx
330
330
Fy
300
380
Fz
380
300
∑
F
590
590
Mx
280
280
My
140
140
Mz
190
190
∑
M
370
370
TDB 58
TDB 78
DND 65
Fx
560
560
Fy
510
620
Fz
620
510
∑
F
980
980
Mx
350
350
My
200
200
Mz
260
260
∑
M
480
480
TDB 120
TDB 170
TDV 120
TDV 170
DND 100
Fx
900
900
Fy
810
1010
Fz
1010
810
∑
F
1580
1580
Mx
440
440
My
260
260
Mz
330
330
∑
M
610
610
TDV 220
TDV 280
DND 125
Fx
1130
1130
Fy
1010
1250
Fz
1250
1010
∑
F
1970
1970
Mx
570
570
My
350
350
Mz
440
440
∑
M
800
800
3.5 Permitted Pressures and Temperatures
In principle, the pressure and temperature values
given in the datasheet and/or order confirmation as
well as the performance label apply. Values (for
pressure and temperature) exceeding these values or
falling below them (for temperature) are not permitted.
If no pressures and/or temperatures are specified in
the data sheet and/or the order confirmation, the
following limits apply for supply pressure and room
temperature:
Supply pressure (system pressure) = Pressure at
the pump intake:
max. 10 bar
Room temperature: max. 40°C
Also obey the applicable laws and regulations when
using the pump (e.g. DIN 4747 or DIN 4752).
Limit Curve as per EN 1092
Max. permissible operating pressure (casing and
flange) applies for the material codes:
F, FB, FN
Limit Curve as per EN 1092
Max. permissible operating pressure (casing and
flange) applies for the material codes:
N, DF, DN, GF, GN