The permitted application conditions and design
details of the delivered pump are shown in the
attached data sheet and / or order confirmation.
3.2 Bearings
TDB design:
Drive-side in the rolling bearings of the
motor. The bearings have lifetime grease lubrication
so that no maintenance is required.
TDV design:
Drive-side: Pressure-side angular ball
bearing (fixed bearing) with relubrication mechanism
(lubrication nipple)
Bearing types
Pump Size
Grease Lubrication
Drive-side Bearing Type
TDV..... (120)
2x 7308 (X arrangement)
TDV..... (170)
2x 7308 (X arrangement)
TDV..... (220)
2x 7310 (X arrangement)
TDV..... (280)
2x 7310 (X arrangement)
TDB and TDV designs:
Intake-side: Medium-lubricated slide bearing in the
intake casing of the pump.
The pump-side slide bearing is lubricated by the
pumped medium.
3.3 Approximate Value for Sound Pressure Level
Nominal
power
P
N
in kW
Sound pressure level L
pA
in dB(A)
Pump alone
Pump + Motor
2950
min
-1
1450
min
-1
2950
min
-1
1450
min
-1
1,5
66,7
65,8
68,2
66,0
2,2
68
67
69,2
67,2
3
69
68,1
71,5
68,3
4
69,9
69
72,1
69,2
5,5
71
70
73,1
70,4
7,5
71,9
71
73,7
71,3
11
73,3
72,3
75,0
73,2
15
74,2
73,3
75,6
74,0
18,5
74,9
74
76,1
74,6
22
75,5
74,5
77,1
75,1
30
76,5
75,6
77,8
76,1
37
77,1
76,2
78,3
76,8
45
77,9
76,9
79,4
77,4
55
78,5
77,5
80,1
78,0
75
79,4
78,5
81,4
78,9
90
80,1
79,1
81,8
79,4
110
80,8
79,8
83,4
80,2
132
81,3
80,4
83,7
80,8
160
81,9
81
84,1
81,3
200
82,7
84,6
250
83,4
86,2
315
84,1
86,6
355
84,6
86,9
Sound pressure level L
pA
measured in 1 m distance
from pump surface acc. to DIN 45635, part 1. Room
and foundation influences are not considered. The
tolerance for these values is
±
3 dB(A).
3.4 Permitted Nozzle Loads and Torques at the
Pump Nozzles ...
The individual forces and individual torques as well as
collective forces and collective torques given in the
table may not be exceeded.
∑
+
+
=
]
[
)
(
2
2
2
N
Fz
Fy
Fx
F
∑
+
+
=
]
[
)
(
2
2
2
Nm
Mz
My
Mx
M
TDB, TDV design
Permissible Forces / Torques on the DNS Suction
Joints
Dimension
Horizontal Suction
Joints,
Any Location
TDB 22
TDB 35
DNS 65
Fx
560
Fy
510
Fz
620
∑
F
980
Mx
350
My
200
Mz
260
∑
M
480
TDB 58
TDB 78
DNS 100
Fx
900
Fy
810
Fz
1010
∑
F
1580
Mx
440
My
260
Mz
330
∑
M
610
TDB 120
TDB 170
TDV 120
TDV 170
DNS 125
Fx
1130
Fy
1010
Fz
1250
∑
F
1970
Mx
570
My
350
Mz
440
∑
M
800
TDV 220
TDV 280
DNS 150
Fx
1350
Fy
1220
Fz
1500
∑
F
2360
Mx
700
My
440
Mz
540
∑
M
990
General Instructions:
Direction of the forces and torques:
Fx ...Force in direction of the x-axis (pump shaft)
Summary of Contents for TDB 120