5. Operating the Cobra 3.1
5.4.5.4 Using the internal Timer
Fig. 18 Screen Settings 1
Fig. 19 Screen Timer-Mode
To change into the Timer-Mode, press
TIMER
at the main screen or press
SETTINGS
—>
TIMER
(Fig. 18).
– On the following Timer Mode-screen (Fig. 19), the pump value (FOG = output) can
be adjusted between 0 and 100%.
Please note that the selected performance curve/characteristic also effects the amount
of the fog output. Thus - although 100% has been adjusted - the output will eventually
be lower. —> See chapter 5.4.1
– For the
ON TIME
(= fogging time), values between 1 - 99 Seconds and for the
OFF
TIME
(= wait time) values between 0.1 - 99.9 Minutes can be adjusted.
– The Timer can be started manually as well as via Remote. To select the starting Mode,
press
TRIGGER
. Depending on the Mode that has been choosen, the screen shows
MAN
or
REM
.
– Furthermore it is possible to program a single timer cycle. Press
ONE PULSE
to ac-
tivate or deactivate this Mode. The machine will then produce fog once with the
programmed duration.
– If you want the Timer to start automatically directly after the working temperature
has been reached, activate
AUTO START
. This is also useful if you will disconnect the
power from the mains during timer operation, and you want the timer to continue
when the power is reconnected.
To activate the Timer, press
ON
. Save the values with
TIMER SAVE
.
To activate or deactivate the Timer manually, press
ACTIVE
respectively
NOT ACTIVE
on the main screen.