![Look Solutions Cobra 3.1 Operating Manual Download Page 16](http://html1.mh-extra.com/html/look-solutions/cobra-3-1/cobra-3-1_operating-manual_1938890016.webp)
16
5. Operating the Cobra 3.1
Fig. 10 Personality „Value“
Fig. 11 Personality „Value + Mode“
The machine can - depending on the choosen Personality - be controlled via one or
two DMX-channels. (Adjustments via
SETTINGS
—>
PERSONALITY
).
– If Personality
VALUE
is choosen, the
Cobra 3.1
can only be controlled via one DMX-
channel. This controls the pump value (= fog output).
– If Personality
VALUE+MODE
has been choosen, the machine can be controlled via
two following DMX-channels. The first channel regulates the pump, the second one
selects the pump mode. —> See chapter 5.4.1.
The second channel is divided into four ranges:
Mode
DMX-Value
Impulse
195 - 255
Extended
130 - 194
Flood
65 - 129
Continuous
0 - 64
The fog output can now be adjusted from 0 - 100% via the DMX-desk.
If you also want to change the Mode (Impulse, Extended, Flood, Continuous) at the
desk, the Personality has to be changed to
Value + Mode
(see below).