5. Operating the Cobra 3.1
5.4.2 Manual Operation
The manual operation is very simple.
The fogging process can be started and stopped by pressing the
START
-button.
The amount of the output can be adjusted by pressing the Plus- and Minus-button
before or while the machine is producing fog.
To open a keyboard where the value can be typed in, press the button in the middle
(FOG).
Please note that the selected performance curve/characteristic also effects the amount
of the fog output. Thus - although 100% has been adjusted - the output will eventually
be lower. —> See chapter 5.4.1
Fig. 5 Manual Mode
The following fogging durations are possible in the
IMPULSE
- and
EXTENDED
-MODE
(measured with Look Regular-Fog, if Look Quick-Fog or Look Slow-Fog is used, the times
can be slightly different):
Pump adjustment
Fogging time in Seconds
IMPULSE-MODE
EXTENDED-MODE
100 %
22 s
55 s
90 %
40 s
76 s
80 %
55 s
95 s
70 %
89 s
128 s
60 %
112 s
176 s
50 %
167 s
347 s
40 %
378 s
more than 10 min/
30 %
Continuous output
Continuous output