1.6.CONVERTING THE GAS-SUPPLY TO THE HOB BURNERS
Burners
: auxiliary, semi-rapid, rapid, treble crown, fish kettle.
These burners are all fitted with injectors designed to create a
primary input of air gauged for each type of gas. This means that
the air regulation does not have to be regulated. Proceed as follows
in order to convert from one type of gas to another:
remove the grids, covers, holed flame diffuser and the
burner supports;
replace the holed injectors as indicated in C according to
the type of gas used (see table 1); put the burner supports, flame diffusers, covers and
grids back in position;
regulate the minimum output following the instructions in paragraph.
1.7.REGULATING THE MINIMUM OUTPUT OF THE HOB BURNERS
Normal/valve taps
Ignite the burners and turn the know to the maximum
position. Remove the knob and insert a small flat-
head screwdriver into the holes on the side of the
control panel, in accordance with the type (fig. A).
Loosen the by-pass screw by two turns in an anti-
clockwise direction and rotate the rod to the
minimum position.
Adjust the previously loosened screws until the flame is lowered but stable, even when rapid
changes are made from the maximum to the minimum position with the burner cold. If safety
taps are fitted, let the burner run on minimum for a few minutes to ensure that the device does
not cut in. If it does, increase the minimum.
N.B. For liquid gas settings, the burner minimum must be set by fully tightening the tap
by-passes.
1.8.CONVERTING THE GAS-SUPPLY TO THE OVEN BURNERS AND GAS GRILL
Oven burners:
To have access to the oven injector proceed as follows:
open the oven door and remove the oven base;
unfasten the screw that secures the burner to the inside of the oven (in the giant oven it
is fixed to the side wall of the muffle) and remove the burner from its seat being careful
not to damage the thermocouple fixed to it;
replace the holed injector in accordance with the type of gas used (see Table 1)
put the burner back into its original position.