7
Set up a correct nosepiece and a correct guide pipe according to the size of
㻌
rivet
㻌
to
㻌
the used.
㻌
(Refer to page 10.)
㻖
Default setup is 3.2 mm-diameter nosepiece and yellow guide pipe.
Fix the end of chute hose to the mandrel
containing case.
Fix the either end of the chute hose to the
containing case or else, so that it does not
loose during operation. There must be
enough space in the end of the chute hose.
Lack of space or obstacles in the end of the
chute hose may prevent a mandrel of cut rivet
from being discharged or cause degradation
in discharge power.
㻖
Be sure to prepare a containing case, to prevent the mandrel from being blasted off .
Cut rivet mandrels may be blasted off from the end of the chute hose and may cause injury.
Prepare an air compressor
. Be sure to place an air fi lter and an air regulator
between the compressor and the air riveter.
Mandrel
Body
Rivet diameter
Classify by color
㻌㻌
A
㻦
Yellow
䚷
B
㻦
White
Guide Pipe
Need Enough
Space
Fix
Rivet Size
(Rivet Diameter)
Nosepiece
Guide Pipe
Φ2.4
2.4
A(Yellow)
Φ3.2
3.2
Φ4.0
4.0
B(White)
Φ4.8
4.8
Complete Air Supply System