6TQWDNG
ᵡᵿᶓᶑᶃ
%QWPVGTOGCUWTG
Rivets cannot be
inserted, of mandrels
cannot be disharged
after cut.
1
Nosepiece is wrongly used.
Use proper Nosepiece with the
rivet size. (Refer to page 7.)
2 Nosepiece or frame head is loosened.
Tighten them up completely.
3
Jaw does not contact with jaw case
head properly.
Clean up the taper area of jaw case
head, and apply lubricant oil to back
䚷
side of jaw. (Refer to page 10.)
4
Size of guide pipe is improper, or guide
pipe is missing.
䚷
Attach proper guide pipe with the rivet
size.
Does not fi nish the
rivet working by sin-
gle stroke.
1
Rivet size is improper with the plate
thickness.
䚷
Use proper rivet.
2 Air pressure of compressor is improper.
Adjust air pressure. (Refer to page 8.)
3
Jaw is worn.
Replace jaw with a new one.
(Refer to page 10.)
4
Jaw case head is not attached properly. Wind and tighten jaw case head to
the end return it to the position where
convex and notch are aligned, then
set up Collar. (Refer to page 11.)
䚷㻌
5
Piston stroke is not enough due to lack
of hydraulic oil.
Refi ll hydraulic oil.(Oil piston stroke is
19mm). (Refer to page 12.)
䚷
Abnormal operation
such that piston
does not work or
moves slowly.
1 Spool doe not work properly.
Clean up spool. (Refer to page 11.)
2
Spool does not work properly because
silencer is clogged.
Replace silencer with a new one.
3
Air piston does not work properly due to
dirty inside of cylinder or lack of oil.
Please contact your distributor.
Power of vacuuming
rivets is weak, or
mandrels are not
discharged.
1
The chute hose is full with mandrels.
Detach the tank unit and make it
empty.
2
Guide pipe of riveter is clogged with
mandrels.
Detach the guide pipe and remove
mandrels.
3
Nozzle unit is dirty.
Clean up the nozzle unit.
(Refer to page 14.)
4
Chute hose is clogged with mandrels.
Detach the chute hose and remove
mandrels.
5
Chute holes is too long (Chute hose
other than specifi ed is used).
Use the specifi ed chute hose.
6
There is an obstacle at the end of chute
hose.
Prepare enough space so that the
䚷
end of the chute hose is not blocked
by an obstacle. (Refer to page 7.)
䚷
7
Air pressure is too low.
Adjust the air pressure to proper
value. (Refer to page 8.)
8
The vacuum air cock opens insuffi
ciently. Turn the air cock to OPEN side
(counter clockwise) to the position it
stops. (Refer to page 9.)
20
⅐ ⁆⁄⁁⁇‴‾‷⁅›⁁⁁⁆※⁀‹
If a problem occurs, check the followings.
If the problem persists after checking the items in the table below, contact your nearest “LOBSTER”
dealer or contact Lobtex.
ᵧᶌᴾ ᶋᵿᶉᶇᶌᶅᴾ ᵿᶌᶗᴾ ᶇᶌᶏᶓᶇᶐᶇᶃᶑᴾ ᵿᶀᶍᶓᶒᴾ ᶒᶆᶇᶑᴾ ᶎᶐᶍᶂᶓᶁᶒᴾ ᶍᶐᴾ ᶐᶃᶏᶓᶃᶑᶒᶑᴾ ᶄᶍᶐᴾ ᶐᶃᶎᵿᶇᶐᴾ ᶕᶍᶐᶉᵊᴾ ᶄᶇᶐᶑᶒᴾ ᶁᶆᶃᶁᶉᴾ ᶒᶆᶃᴾ ᶒᶐᶍᶓᶀᶊᶃᶑᶆᶍᶍᶒᶇᶌᶅᴾ
ᶇᶒᶃᶋᶑᴾᶀᶃᶊᶍᶕᴾᵿᶌᶂᴾᶒᶆᶃᶌᴾᶋᵿᶉᶃᴾᵿᴾᶌᶍᶒᶃᴾᶍᶄᴾᶒᶆᶃᴾᶋᶍᶂᶃᶊᴾᶌᶓᶋᶀᶃᶐᵊᴾᶒᶆᶃᴾᶓᶑᵿᶅᶃᴾᶁᶍᶌᶂᶇᶒᶇᶍᶌᶑᴾᵿᶌᶂᴾᶒᶆᶃᴾᶒᶐᶍᶓᶀᶊᶃᴾᶑᶗᶋᶎᶒᶍᶋᶑᴾ
ᶇᶌᴾᵿᶑᴾᶋᶓᶁᶆᴾᶂᶃᶒᵿᶇᶊᴾᵿᶑᴾᶎᶍᶑᶑᶇᶀᶊᶃᵌᴾᵧᶄᴾᶗᶍᶓᴾᶁᵿᶌᴾᶎᶐᶍᶔᶇᶂᶃᴾᶒᶆᶇᶑᴾᶉᶇᶌᶂᴾᶍᶄᴾᶇᶌᶄᶍᶐᶋᵿᶒᶇᶍᶌᵊᴾᶇᶒᴾᶋᵿᶗᴾᶐᶃᶂᶓᶁᶃᴾᶒᶆᶃᴾᵿᶋᶍᶓᶌᶒᴾᶍᶄᴾ
ᶒᶇᶋᶃᴾᶐᶃᶏᶓᶇᶐᶃᶂᴾᶄᶍᶐᴾᶂᶃᶊᶇᶔᶃᶐᶗᴾᶍᶐᴾᶐᶃᶎᵿᶇᶐᶑᴾᶒᶍᴾᶀᶃᴾᶁᶍᶋᶎᶊᶃᶒᶃᶂᵌ