14
CHAPTER 4: OPERATION
MOVE S2
The air is conditioned by a dedicated unit, to eliminate the humidity and protect the pneumatic
components.
The air filtering device serves to filter air and to
set its pressure before it is distributed into the
pneumatic circuit of the bar feeder.
The air must be furnished at a maximum
pressure of 6 bar (minimum 5 bar), and
whenever possible, clean and dry.
A
Pressure regulator
B
Pressure gauge
C
Inlet
D
Regulated pressure outlet
E
Decanter
F
Automatic purging
The pneumatic connection (C) is located behind the control cabinet.
For the pneumatic connections of the bar feeder, the customer must provide a hose (B) with an inside
diameter of 1/2" (12.7 mm). For USA, 3/8" (9.5 mm).
Provide an air hose long enough to allow the complete travel (500 mm) of the retraction system.
When the hose is connected, it should not lie on the
ground because it could become damaged.
1.
Place clamp (A) around hose (B).
2.
Insert fitting (C) into hose.
3.
Tighten the flange (A) to make it airtight.
1.
Unlock the adjusting knob by pulling it upward.
2.
To increase the pressure, turn it clockwise. To decrease it, turn it
in the opposite direction. The operational pressure should be set
at 5 bar.
3.
When the settings are done, lock the adjuster by pushing it
downward.
Summary of Contents for QUICK SIX S2
Page 1: ......
Page 2: ...MOVE S2...
Page 3: ...MOVE S2...
Page 4: ...MOVE S2...
Page 5: ...CHAPTER 1 BASIC NOTIONS 3 MOVE S2...
Page 13: ...CHAPTER 2 TECHNICAL DATA 11 MOVE S2...
Page 15: ...CHAPTER 2 TECHNICAL DATA 13 MOVE S2...
Page 16: ...14 CHAPTER 2 TECHNICAL DATA MOVE S2...
Page 18: ...16 CHAPTER 2 TECHNICAL DATA MOVE S2...
Page 19: ...CHAPTER 3 SETTING INTO OPERATION 17 MOVE S2...
Page 33: ...CHAPTER 4 OPERATION 31 MOVE S2...
Page 57: ...CHAPTER 4 OPERATION 1 MOVE S2...
Page 60: ...4 CHAPTER 4 OPERATION MOVE S2...
Page 73: ...CHAPTER 4 OPERATION 17 MOVE S2...
Page 75: ...CHAPTER 4 OPERATION 1 MOVE S2...