Chapter 3: Procedures
3-7
HYDROBAR EXPRESS 220
Step 4: Confirm that the shield is flush against the measuring cell bracket. If not, loosen the split collar with a 5mm hex key and
readjust. When the shield is adjusted correctly, retighten the split collar.
Step 5: Push the measuring cell shield back down.
Split collar
Measuring
acket
cell br
Shield
Shield
Step 6: Adjust the range of the sensor by placing your hand below the channel and adjusting the yellow screw on SQ1. Adjust the
screw until the light on SQ1 illuminates (the sensor will detect your hand and the range has been set).
Light
Yellow screw
Step 7: Place a short piece of material (8 or 11mm) in the guiding channel. (A straight section of a wire coat hanger will work if
needed) Place the material so that an inch or more sticks out of the channel and is under SQ1.
Bar stock should
stick out of the
channel