Chapter 5: Preventative Maintenance
5-3
HYDROBAR EXPRESS 220
Annual Maintenance
Check the PLC battery
The PLC backup battery saves the PLC program in case of any power failure. The battery used in the SAIA PCD2 is a non-
rechargeable 3VDC Lithium/ CD2032 battery. Over time, the battery will slowly discharge and an alarm message will appear on the
remote control station (
). The following chart shows the average life expectancy of the battery:
Use of Automation
Avg Life
Expectancy:
25°C
Avg Life
Expectancy:
55°C
100% off
0% on
3 years
6 months
0% off
100% on
5 years
4 years
30% off
70% on
4 years
1 year
Verify the alignment of the bar feeder
Check alignment of bar feeder to lathe spindle to make sure neither have shifted.