Chapter 1: Alarms
HYDROBAR EXPRESS 220
1-19
Default Prior to Closing the Guiding Channel
DEFAULT PRIOR TO
CLOSING THE GUIDING
CHANNEL!
POSSIBLE CAUSES:
-SIGNAL SWITCH SQ4
DEFECTIVE OR
MIS-ADJUSTED
Description:
The Default Prior To Closing The Guiding Channel alarm occurs if input (I1.2 – SQ4) is already on before the channel before the
channel tries to close to insert the new bar into the collet of the bar feed.
Solution:
Case Input Remote
Pendant
Solution
1
Bit 2 = 1
MODULE 1
76543210
100
The switch may be sticking and needs to be replaced.
2
Bit 2 = 0
MODULE 1
76543210
0
Alarm needs to be cleared. Press the STOP key on the remote
control station to clear the message and reset the alarm.
For case 1, after the solution has been completed, press the STOP key on the remote control station to clear the message and reset
the alarm.