3-20
Chapter 3: Procedures
HYDROBAR EXPRESS 220
Channel Lid Switches (SQ3 &SQ4) Adjustment
The purpose of this procedure is to adjust SQ3 and SQ4 switches.
Tools List:
•
5mm hex key
Procedure
Conditions:
•
Main guiding channels open
•
Turn main bar feed power off.
Step 1: Loosen the split collar that is closest to SQ3 with a 5mm hex key.
SQ3
SQ4
SQ3
Step 2: Set the gap to 0.5 - 0.6mm with a feeler gauge between SQ3 and the plate.
Split Collar
0.5 - 0.6 gap
Plate