3-6
Chapter 3: Procedures
HYDROBAR EXPRESS 220
SQ1 Measuring Cell Adjustment
This procedure is used to adjust SQ1 measuring cell. SQ1 detects the face of the present bar being loaded and calculates the length
of the bar.
Tools List:
•
Small flat screw driver
•
2.5mm hex key
•
5mm hex key
•
7mm combination wrench
•
One 8 or 11mm guiding channel
•
Short piece of round material: 1/8” or smaller
Procedure
Conditions:
•
Main guiding channel open
•
Main bar feed power on
Step 1: Install an 8 or 11mm guiding channel in the front channel location closest to the lathe.
Step 2: Pull up on the air regulator knob and turn it counter clockwise to drop the air pressure to 0 (zero).
Front channel –
closest to the lathe
Knob
Step 3: Pull up the measuring cell shield.
Measuring
cell shield
SQ1
SQ1