Chapter 1: Alarms
HYDROBAR EXPRESS 220
1-21
Servo Motor Positioning Error
SERVO MOTOR
POSITIONING
FOLLOWING ERROR!
DURNG SEQUENCE
NUMBER [@@]
POSSIBLE CAUSE:
MECHANICAL OBSTACLE
PREVENTS BAR STOCK
TO FEED OUT
Description:
The Servo Motor Following Error alarm occurs due to a mechanical obstacle preventing the bar stock from feeding out. The torque on
the servo motor will build up when the obstacle prohibits the stock from moving, once the torque reaches a certain limit the PLC
instructs the servo amplifier to quit pushing and this alarm message appears on the remote control station.
Solution:
Seq. #
Solution
##
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the
alarm.
•
Check for any mechanical obstacles that the bar stock may be hitting. Remove obstacle if this is the case.
•
Check the bar stock diameter. Make sure that the actual diameter is the same as the value entered in for the
corresponding parameter in the
Part Setup
menu.
•
Check the alignment between the bar feeder and the lathe. The lathe or the bar feeder may have shifted over
a long period if either is not lagged to the floor securely.
If the problem persists please contact LNS America, Inc. for further information.
Summary of Contents for Hydrobar Express 220
Page 61: ......
Page 143: ......
Page 147: ......
Page 156: ...Chapter 6 Spare Parts 6 9 HYDROBAR EXPRESS 220 Servo Motor Assembly ...
Page 161: ...6 14 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Hydraulic Pump Assembly ...
Page 163: ...6 16 Chapter 6 Spare Parts HYDROBAR EXPRESS 220 Diameter Adjustment Motor Assembly ...
Page 164: ...Chapter 6 Spare Parts 6 17 HYDROBAR EXPRESS 220 Air Regulator and Cable Passage Plate ...