CHAPTER 8 ELECTRICAL
BUCK 450 SERVICE MANUAL 20.0
CHAPTER 8 ELECTRICAL PAGE 8-
19
1.2
Fan motor (inspection 2)
Turn the main switch to off.
Remove the thermo switch lead
from thermo switch.
Connect the two wires of the
thermo switch.
Turn the main switch to on
DOES
NOT
MOVE
The wiring circuit from battery to fan
motor is faulty. Repair
5. Thermo switch
Remove the thermo switch from the
radiator.
Connect the pocket tester
(ΩX1)
to
the thermo switch
.
Immerse the thermo switch in the
water
Check the thermo switch for
continuity.
NOTE:
Measure
temperatures
while
heating the coolant with the
temperature gauge
WARNING
Handle the thermo switch with
special care.
Never subject it to strong shocks or
allow it to be dropped. Should it be
dropped, it must be replaced.
Do not touch the thermo switch to
the bottom of the heated vessel.
88±3
℃
Thermo switch “ON”
80±3
℃
Thermo switch “OFF”
OUT OF SPECIFICATION
Replace the thermo switch
Summary of Contents for ARCHON 400
Page 1: ...SERVICE MANUAL ARCHON 400...
Page 25: ...CHAPTER 2 MAINTENANCE BUCK 450 SERVICE MANUAL 20 0 NOTES CHAPTER 2 MAINTENANCE PAGE 2 14...
Page 41: ...CHAPTER 3 ENGINE BUCK 450 SERVICE MANUAL 20 0 3 3 CYLINDER HEAD CHAPTER 3 ENGINE PAGE 3 16...
Page 112: ...CHAPTER 3 ENGINE BUCK 450 SERVICE MANUAL 20 0 NOTES CHAPTER 3 ENGINE PAGE 3 87...
Page 122: ...CHAPTER 4 CHASSIS BUCK 450 SERVICE MANUAL 20 0 CHAPTER 4 CHASSIS PAGE 4 10 NOTES...
Page 156: ...CHAPTER 5 FINAL DRIVE BUCK 450 SERVICE MANUAL 20 0 CHAPTER 5 FINAL DRIVE 5 34 NOTES...
Page 169: ...CHAPTER 6 TRANSMISSION BUCK 450 SERVICE MANUAL 20 0 CHAPTER 6 TRANSMISSION PAGE 6 13 NOTES...
Page 184: ...CHAPTER 7 BRAKES BUCK 450 SERVICE MANUAL 20 0 CHAPTER 7 BRAKES PAGE 7 15 NOTES...