-29-
Change Data Format
Touch [Change display] in the bottom to change the data format. Data format
is selectable from “Communication data” and “analog data of external input”.
[Communication Data]
[Analog data of external input]
Each data is displayed in specific colors. CAN frame -> yellow. LIN frame ->
green. External input data -> white
Display
Description
Time stamp Time of receiving frames (H / M / S / ms)
( :
Matched with trigger condition
)
SyPID
Sync byte field and Protected ID field of LIN (in HEX).
ID
Standard / expansion ID of CAN, or LIN frame ID (in HEX).
Type
Frame type.
Data
Data frame of CAN.
Remote
Remote frame of CAN
Frame
Frame of LIN.
Illegal
Illegal frame of LIN
Unknown data on the LIN bus.
----
Supplemental data for external input.
DLC
Data length code of CAN, or DL set in the LIN configuration (in
decimal).
(If frame end time is set as “time” in LIN Configuration, this will
not be displayed.)
St
Frame status.
Normal frame.
Sync Byte Field error of LIN (other than 55h).
Parity error of LIN.
Long data error of LIN.
Non-response data of LIN (less than 1 byte)
Checksum error of LIN.