Owner’s Manual
Hydraulic pump 609-29232-1 Single-line with 165-l container
4.1EN-68607-G09
Subject to changes
Page 6 of 15
LINCOLN GmbH Postfach 1263 D-69183 Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) 33-259
Settings
(Fig.3: Oscillating cylinder)
1. Flow regulating valve (item 1)
The travelling speed of the cylinder is determined by the
supplied quantity of oil. The operating range of the flow
regulating valve is between 2 l/min and 20 l/min. Turning
the set screw (item 5) clockwise increases the oil
quantity. Turning the set screw counter clockwise
reduces the oil quantity. After completing the
adjustment, tighten the set screw with the counter nut
(item 3, SW 17).
2. Pressure reducing valve (item 2)
The max. inlet pressure is 200 bar. The pressure
reducing valve allows the operating pressure to be set
between 12 and 140 bar.
Turning the set screw (item 5) clockwise increases the
operating pressure. Turning the set screw counter
clockwise reduces the operating pressure. After
completing the adjustment, tighten the set screw with
the counter nut (item 4, SW 19).
To control the set operating pressure, one can connect
a measuring device to the connection M.
The operating pressure must be selected in such a way
that the max. permissible supply pressure of the pump
and the max. system pressure of the system are not
exceeded.