background image

1

THESE ARE CAT II

2H3 

+ APPLIANCES

01773 828100

I N   W A R R A N T Y

T E C H N I C A L   H E L P L I N E

01773 828400

O P A L I A

Summary of Contents for OPALIA X13

Page 1: ...1 THESE ARE CAT II2H3 APPLIANCES 01773 828100 IN WARRANTY TECHNICAL HELPLINE 01773 828400 O P A L I A ...

Page 2: ...ver the rate at which water is drawn there will be instantaneous hot water at a very nearly constant temperature within the maximum capacity of the appliance The ignition system on this water heater with no permanent pilot has been designed to achieve maximum energy saving INSTALLATION AND USER INSTRUCTIONS UK OPALIA X13 Mandatory warning notice for CEE countries WARNING this appliance was designe...

Page 3: ...us size spouts are available Please contact your supplier HEATER SCHEMATIC 1 Air pressure switch 2 Fan 3 Overheat cut out system 4 Ignition electrode 5 Flame sense electrode 6 Gas valve 7 Temperature sensor 8 Flow sensor 9 Control PCB 10 Temperature adjustment 11 Heat exchanger 1 3 5 6 7 2 4 11 8 9 10 1 mini Incoming air Outlet of combustion products Shy 112a slope of 35 mm per metre min ...

Page 4: ...Refer to the data badge for exact type of appliance and the gases it is suitable for Variable output of 8 7 kW 29665 Btu h to 22 7 kW 77403 Btu h Efficiency 78 4 Minimum flow rate hot water temperature to maxi position 2 7 l min 0 60 g min mini position 4 2 l min 0 92 g min Maximum flow rate by flow limiter 3 l min 2 86 g min Specific flow rate t 30 C 11 l min 2 42 g min Minimum water pressure pw ...

Page 5: ... exceeds 7 5 m include adapter TWIN PIPE FLUE 2 x Ø 80 mm Important remove the flue restrictor ring when L exceeds 1 m Important remove the flue restrictor ring when L exceeds 4 m Maximum flue index 60 Pa This value is reached when L1 L2 exceeds 11 m includes elbows and terminal Important remove the flue restrictor ring when L1 L2 exceeds 8 m The flue must be fitted with a minimum slope of 35 mm p...

Page 6: ...supply Ensure that the live and neutral are connected correctly To comply with current standards this connector must be made through a double pole switch with a contact separation of no less than 3 mm FLUE LOCATION Minimum dimensions in mm for the positioning of flue terminals N C D M A B E F G I H L Ven 060b A Under a window 600 B Under an air vent 600 C Under a gutter 300 D Under a balcony 300 E...

Page 7: ...function or an abnormality gives rise to the disconnection of the appliance and the safety indicator 4 lights To restart the water heater press the RESET button 3 SAFETY DEVICES Air flow safety device air pressure switch In the event of even partial blockage of the flue for whatever reason resulting in a reduced air flow the water heater s built in safety device comes into operation the burner is ...

Page 8: ... gas supply Shut off water supply open all hot water taps If the kind of gas supplying the appliance is changed certain parts of the burner and pilot need to be modified These modifications and the new adjustments they involve must only be carried out by a qualified engineer Toensurethecontinuedefficientandsafeoperation of the water heater it is recommended that it is checked and serviced annually...

Page 9: ...heck electrode lead change if necessary check flame sense lead change if necessary change ignition PCB change main PCB no electrical supply no gas flow gas valve reversed live and neutral flue system ignition system the water heater will not run but the safety indicator light is not lit the water heater will not run safety disconnection the spark train does not light the burner safety disconnectio...

Page 10: ...ve ignition module water flow sensor Diag B connections to main PCB behind control housing Diag C controls gas and water connections Diag D fan connections Diag E gas valve modulator connections Diag F temperature sensor connections Diag G air pressure switch connections Diag H overheat thermostat connections Diag I flow sensor Diag J ignition and flame sense electrodes ...

Page 11: ... improve the quality of its appliances Saunier Duval reserves the right to modify the latter without prior notice The technical information contained in our documents are given for guidance only and are without liability ...

Page 12: ...12 106201 E 07 99 ...

Reviews: