COMMISSIONING AND LIGHTING

1 -

ON / OFF button

2 -

hot water temp adjustment

3 -

reset button

4 -

safety indicator

1

2

3

4

Hab 220

Start-up

Turn the ON / OFF button to 

ON

Open a draw OFF tap

Turn the temperature adjustment to obtain the

desired temperature

Stopping the water-heater

Turn the ON / OFF button to 

OFF

In this position the least hottest
water temperature is obtained
(~ 40 

°

C)

Hab 236

Hab 237

Hot water temperature adjustment

In this position the hottest water
temperature is obtained (up to
60 

°

C for a minimal flow rate)

Operating principles

The 

OPALIA X13

 water-heater operates with no per-

manent pilot :

-

when a hot water tap is opened, the gas entering

the burner is ignited by a spark train emitted by the
ignition electrode. A second electrode checks for
the presence of a flame at the burner, the appliance
is shut down by disconnection;

-

 when the hot water tap is closed, the gas input is

cut off by the valve and the appliance is shut down.

IMPORTANT : before operating the boiler, remove
the two fan transit packing pieces

Safety shutdown

A malfunction or an abnormality gives rise to the

disconnection of the appliance, and the safety

indicator (

4

) lights ...............................................

To restart the water-heater,

press the RESET button (

3

) ..................................

SAFETY DEVICES

Air flow safety device (air pressure switch )

In the event of even
partial blockage of the
flue, for whatever reason
resulting in a reduced air
flow, the water-heater’s
built-in safety device
comes into operation :
the burner is shut down
whilst the fan continues to operate. The water-
heater is ready to operate as soon as the fault has
been rectified.

In the event of loss of gas supply

The safety device automatically disconnects the

water-heater. When the gas supply is restored, press

the "RESET" button

.

In the event of a power cut

The water-heater will cease to operate. When the
electricity supply is restored, the heater will auto-
matically restart.

Overheat cutout device

If anything occurs
which results in the
over heat cutout
device shutting down
the water-heater,
please call your nearest
approved after-sales
organisation.

IMPORTANT : 

It is

forbidden to bypass or tamper with any of the safety
devices. If, after attempting to use the heater, a
safety shut-down condition occurs, this must be
rectified immediately by a qualified, competent
person.

Sec 045

Sec 044

Summary of Contents for OPALIA X13

Page 1: ...1 THESE ARE CAT II2H3 APPLIANCES 01773 828100 IN WARRANTY TECHNICAL HELPLINE 01773 828400 O P A L I A ...

Page 2: ...ver the rate at which water is drawn there will be instantaneous hot water at a very nearly constant temperature within the maximum capacity of the appliance The ignition system on this water heater with no permanent pilot has been designed to achieve maximum energy saving INSTALLATION AND USER INSTRUCTIONS UK OPALIA X13 Mandatory warning notice for CEE countries WARNING this appliance was designe...

Page 3: ...us size spouts are available Please contact your supplier HEATER SCHEMATIC 1 Air pressure switch 2 Fan 3 Overheat cut out system 4 Ignition electrode 5 Flame sense electrode 6 Gas valve 7 Temperature sensor 8 Flow sensor 9 Control PCB 10 Temperature adjustment 11 Heat exchanger 1 3 5 6 7 2 4 11 8 9 10 1 mini Incoming air Outlet of combustion products Shy 112a slope of 35 mm per metre min ...

Page 4: ...Refer to the data badge for exact type of appliance and the gases it is suitable for Variable output of 8 7 kW 29665 Btu h to 22 7 kW 77403 Btu h Efficiency 78 4 Minimum flow rate hot water temperature to maxi position 2 7 l min 0 60 g min mini position 4 2 l min 0 92 g min Maximum flow rate by flow limiter 3 l min 2 86 g min Specific flow rate t 30 C 11 l min 2 42 g min Minimum water pressure pw ...

Page 5: ... exceeds 7 5 m include adapter TWIN PIPE FLUE 2 x Ø 80 mm Important remove the flue restrictor ring when L exceeds 1 m Important remove the flue restrictor ring when L exceeds 4 m Maximum flue index 60 Pa This value is reached when L1 L2 exceeds 11 m includes elbows and terminal Important remove the flue restrictor ring when L1 L2 exceeds 8 m The flue must be fitted with a minimum slope of 35 mm p...

Page 6: ...supply Ensure that the live and neutral are connected correctly To comply with current standards this connector must be made through a double pole switch with a contact separation of no less than 3 mm FLUE LOCATION Minimum dimensions in mm for the positioning of flue terminals N C D M A B E F G I H L Ven 060b A Under a window 600 B Under an air vent 600 C Under a gutter 300 D Under a balcony 300 E...

Page 7: ...function or an abnormality gives rise to the disconnection of the appliance and the safety indicator 4 lights To restart the water heater press the RESET button 3 SAFETY DEVICES Air flow safety device air pressure switch In the event of even partial blockage of the flue for whatever reason resulting in a reduced air flow the water heater s built in safety device comes into operation the burner is ...

Page 8: ... gas supply Shut off water supply open all hot water taps If the kind of gas supplying the appliance is changed certain parts of the burner and pilot need to be modified These modifications and the new adjustments they involve must only be carried out by a qualified engineer Toensurethecontinuedefficientandsafeoperation of the water heater it is recommended that it is checked and serviced annually...

Page 9: ...heck electrode lead change if necessary check flame sense lead change if necessary change ignition PCB change main PCB no electrical supply no gas flow gas valve reversed live and neutral flue system ignition system the water heater will not run but the safety indicator light is not lit the water heater will not run safety disconnection the spark train does not light the burner safety disconnectio...

Page 10: ...ve ignition module water flow sensor Diag B connections to main PCB behind control housing Diag C controls gas and water connections Diag D fan connections Diag E gas valve modulator connections Diag F temperature sensor connections Diag G air pressure switch connections Diag H overheat thermostat connections Diag I flow sensor Diag J ignition and flame sense electrodes ...

Page 11: ... improve the quality of its appliances Saunier Duval reserves the right to modify the latter without prior notice The technical information contained in our documents are given for guidance only and are without liability ...

Page 12: ...12 106201 E 07 99 ...

Reviews: