Mechanical Installation
µSDM-1RD / µSDM-1 / µSDM-1E IOM
4-18
Lightscape Networks Ltd. Proprietary
426006-2304-013-B1
4-13 shows an internal view of the major areas and components of an indoor
cabinet equipped with a 120
Ω
4-14 shows an internal view of the
major areas and components of an indoor cabinet equipped with a 75
Ω
DDF.
The cabinet equipment includes:
♦
DDF, two options: coax (75
Ω
) or Krone (120
Ω
) type connections
♦
Circuit breaker and terminal blocks for power connections. The circuit
breaker box is shielded with a protective cover; a window on the protective
cover can be opened to access the circuit breakers.
♦
AC to DC power supply
♦
ODF: TM or ADM (optional)
4.4.4 Completing the Indoor Cabinet Installation
1. Assemble the cabinet to the wall with four securing screws
2. Connect the AC mains or DC power to the circuit breaker.
3. Mount the multiplexer in the designated bracket; complete the attachment
with the two captive screws at the base of the bracket.