AireLink
60 Installation and User Manual Rev. D
Networking, Power and Service Connections
Page 47
In addition, and where applicable, we recommend following the IEC 61024/ IEC 62305 standards for
proper lightning protection and install the antennas within the lightning protection zone LPZ O
B
where
the equipment is not subject to direct lightning strikes (See Fig. 3-7).
1
IEC 61024
When the linkhead is located near another grounded/earthed object, such as a tower, lightning
(Franklin) rod or any type of mast or pole, it may fall under the zone of protection provided by the tower
or mast.
Even if it is not under the Zone, if it is not a good path to ground/earth it is less likely to be destroyed by
lightning.
2
High Lightning zones
It is possible to deliberately place a protective mast near the linkhead to provide this type of zone. In
this case the linkhead is protected by the mast and is further protected by not being a good path to
ground/earth for the lightning.
The mast should have a sharp point at the top. This encourages the formation of the lightning strike
where the electrons are concentrated at the tip of the rod and further protects the equipment
3
Towers
A linkhead mounted on a tower is almost always within the LPZ O
B
zone and has some protection simply
because of its location.
Figure 3-7: Lightning Protection Zones
Summary of Contents for AireLink 60
Page 1: ...LightPointe AireLink 60 Installation and User Manual...
Page 28: ...AireLink 60 Installation and User Manual Rev D Introduction Page 28...
Page 40: ...AireLink 60 Installation and User Manual Rev D Surveying the Installation Site Page 40...
Page 56: ...AireLink 60 Installation and User Manual Rev D Recommended Software Pre Configurations Page 56...
Page 81: ...AireLink 60 Installation and User Manual Rev D System Installation Page 81...
Page 112: ...AireLink 60 Installation and User Manual Rev D CLI Command Line Interface Page 112...
Page 116: ...AireLink 60 Installation and User Manual Rev D Bluetooth AireLink Viewer Page 116...
Page 121: ...AireLink 60 Installation and User Manual Rev D SNMP Page 121...
Page 125: ...AireLink 60 Installation and User Manual Rev D Troubleshooting and Diagnostics Page 125...
Page 129: ...AireLink 60 Installation and User Manual Rev D Advanced Troubleshooting Methods Page 129...
Page 133: ...AireLink 60 Installation and User Manual Rev D Technical Support Page 133...