AireLink
60 Installation and User Manual Rev. D
Introduction
Page 14
Industry Canada’s RSS-102 requirement are listed below and are slightly different from the FCC
regulation.
A calculation was perform to confirm the required safe distance for fixed service devices.
Limit for power density for general population/uncontrolled exposure was calculated for a power
density of max. 1 mW/cm
2
and for the frequency range 1500 -100000 MHz.
The power density P (mW/cm
2
) = P
T
/ 4πr
2
, where
P
T
= the maximum equivalent isotropically radiated power (EIRP).
The minimum safe distance “r”, where RF exposure does not exceed the permissible limit, is:
r = sqrt { PT/ (Px4π)}
1.
AireLink™ 60 SX system with 12 cm lens antenna
The maximum rms output power is 9.1 dBm and max antenna gain is 36 dBi. This corresponds to the
equivalent isotropically radiated power (EIRP) of 9.1 dBm + 36 dBi = 45.1 dBm, which is equal to
32359 mW.
r = sqrt { PT/ (Px4π)} = sqrt {32359 / 12.56} =
50 cm or 1.7 feet
Summary of Contents for AireLink 60
Page 1: ...LightPointe AireLink 60 Installation and User Manual...
Page 28: ...AireLink 60 Installation and User Manual Rev D Introduction Page 28...
Page 40: ...AireLink 60 Installation and User Manual Rev D Surveying the Installation Site Page 40...
Page 56: ...AireLink 60 Installation and User Manual Rev D Recommended Software Pre Configurations Page 56...
Page 81: ...AireLink 60 Installation and User Manual Rev D System Installation Page 81...
Page 112: ...AireLink 60 Installation and User Manual Rev D CLI Command Line Interface Page 112...
Page 116: ...AireLink 60 Installation and User Manual Rev D Bluetooth AireLink Viewer Page 116...
Page 121: ...AireLink 60 Installation and User Manual Rev D SNMP Page 121...
Page 125: ...AireLink 60 Installation and User Manual Rev D Troubleshooting and Diagnostics Page 125...
Page 129: ...AireLink 60 Installation and User Manual Rev D Advanced Troubleshooting Methods Page 129...
Page 133: ...AireLink 60 Installation and User Manual Rev D Technical Support Page 133...