Liberty Pumps ProVore PRG101A Installation Manual Download Page 3

 

      ©Copyright 2013 Liberty Pumps Inc.    All rights reserved  

- 3 - 

 

2.

  x 

Introduction   

                 x

 

 

   

 

 

INTRODUCTION 

This manual  was prepared to  assist  you  in the correct installation,  operation, and maintenance of  your Liberty 

pump.  Please read it completely before installing the pump.  Make certain that you are familiar with the contents, 

and the chapters on installation and operation are fully understood before running the pump. 

 

Liberty  Pumps  are  designed  for  minimal  maintenance.    However,  regular  checks  will  ensure  longer  life  and 

greater operating reliability. 

 

WARRANTY:

  No repair work should be carried out during the warranty period without prior factory approval.  To 

do so may render the warranty void. 

SERIAL #:

 In all correspondence and reports, make certain that the pump serial number is given. 

 

DESIGN OF PUMP 

The grinder pump contains metal parts that rotate at high speeds.  Be careful around 

pump base while power is connected.  Make sure that the pump is either in the tank or 

clear from people and wires when in operation. 

 

1.  Liberty ProVore

®

  Series grinder pumps are designed for continuous underwater operation.  The motor and 

pump form a close coupled, watertight unit.  The induction motor is insulated against heat and moisture, Class 

B insulation.  

 

2.  A thermal overload protector is imbedded in the stator windings.  This is connected in series and wired to shut 

down the pump if overheating occurs.  The overload switch resets automatically when the motor cools. 

 

3.  The motor is protected against damage from water entry by a mechanical type cartridge seal with two silicon-

carbide faces. 

 

4.  The impeller and volute are designed for efficient flow characteristics and clog-free operation.  The hardened 

cutters grind solids and fibrous matter into small particles that can be safely pumped through small diameter 

piping. 

 

5.  For sewage systems, consult local plumbing codes on requirements for venting the tank.  The pump shall not 

be  installed  in  locations  classified  as  hazardous  in  accordance  with  the  National  Electrical  Code,  ANSI/ 

NFPA70. 

 

NOTE:  The primary material of the Liberty PRG Series Pumps is cast iron, elastomers are Buna-N.  They 

should not be used to pump corrosive liquids. 

 

 

3.

  

 

X

 Mechanical Installation      

  x

  

 

 

 

INSPECTION UPON RECEIPT 

The  shipping  container  should  be  immediately  inspected  for  damage  that  may  have  occurred  in  shipment.  

Exercise  care  in  opening  the  shipping  container  to  avoid  damage  to  the  pump.    Remove  any  blocking  and 

cushioning from within the container.   

 

Check all cushioning for spare parts before discarding.  Visually check the pump and any spare parts for damage.  

Check for damaged electrical wires, especially  where they exit the motor housing.  Contact the Liberty Pumps 

Customer Service Department to report any damage or shortage of parts.  The cutter located on the bottom of the 

unit should be turned several rotations with the use of a 6 mm hex wrench, it should rotate freely without rubbing 

on the cutter plate.  This will insure that the impeller and cutter are free of any seizure due to prolonged storage.  

If the impeller is not rotated manually prior to installation, the pump may fail to activate.  If the impeller’s rotation is 

difficult or completely resistant, contact the Liberty Pumps Customer Service Department. 

Summary of Contents for ProVore PRG101A

Page 1: ...r cord PRG102M 2 1 hp 230V 1 phase 25 Power cord Do not throw away or lose this manual Contents General Information Introduction Mechanical Installation Electrical Connection Operation Troubleshooting...

Page 2: ...adequate protective clothing when working on a used pump or piping Never enter a pump basin after it has been used Sewage and effluent can emit several gases which are poisonous Keep clear of suction...

Page 3: ...l type cartridge seal with two silicon carbide faces 4 The impeller and volute are designed for efficient flow characteristics and clog free operation The hardened cutters grind solids and fibrous mat...

Page 4: ...ending on local codes and the number of fixture units entering the system Check with the local authorities or contact Liberty Pumps if you are unsure of the proper basin size Installation should be at...

Page 5: ...ent plug To reduce the risk of electric shock be certain that the grounding conductor is connected only to a properly grounded control panel or if equipped with a grounding type plug that it is connec...

Page 6: ...switch cord to the discharge pipe NOTE A minimum cord length of 3 5 from the tether point to the top surface of the float is required for proper switch operation If using a differential other than th...

Page 7: ...Refer to panel or switch instructions for proper electrical connection FLOAT SEQUENCE PIGGY BACK SWITCH AUTOMATIC MODELS 1 As the liquid level in the wet well rises the float tilts closing the switch...

Page 8: ...ump Off Factory set Float tether 3 5 Pump On Factory set Float tether 3 5 SIMPLEX PUMP STATION 3 Float System Pump Off Level to top of motor housing Pump On Minimum 1 1 2 ft above Pump Off Level High...

Page 9: ...IFY THE LIBERTY PRODUCT SERVICE DEPARTMENT IMMEDIATELY DO NOT SWITCH THE POWER SUPPLY LEADS DO NOT OPERATE THE PUMP ALWAYS ENSURE THAT THE PUMP IS FREE OF WIRES OR OTHER OBSTRUCTIONS THAT MAY CAUSE HA...

Page 10: ...ischarge line passes through or into cold areas Check valve is stuck closed or installed backwards Remove check valve s and examine for freedom of operation and proper installation Gate or ball valve...

Page 11: ...installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduced in size if the pump has been used i...

Page 12: ...sica cord n el ctrico de 10 pies 3 m PRG102M 2 1 hp 230 V monof sica cord n el ctrico de 25 pies 8 3 m No tire ni pierda este manual Manual de instalaci n 2399000B Bombas trituradoras residenciales Pr...

Page 13: ...grese a una cubeta de bomba despu s que haya sido usada Los sistemas de efluentes y de alcantarillado pueden emitir diferentes tipos de gases t xicos Mant ngase alejado de la entrada de succi n y de l...

Page 14: ...de carburo de silicio 4 El rotor y la voluta est n dise ados para producir un caudal ptimo y funcionar sin obstrucciones Los discos endurecidos trituran la materia s lida y fibrosa hasta convertirla...

Page 15: ...undidad suficiente como para que todas las ca er as queden por debajo de la l nea de penetraci n de la helada Si esto no fuera posible desmonte la v lvula de retenci n y modifique el tama o de la cube...

Page 16: ...conectado debidamente a un panel de control a tierra o si cuenta con un enchufe a tierra tendr que enchufarse a un tomacorriente conectado a tierra NO derive los cables de puesta a tierra ni retire l...

Page 17: ...lotador para que el interruptor funcione correctamente Si se va a utilizar un diferencial distinto al de f brica se deber ajustar de forma que la bomba se apague cuando queden 15 24 cm 6 pulg como m n...

Page 18: ...OS 1 El flotador se va inclinando a medida que sube el nivel del sumidero inundado con lo que cierra el interruptor Esto hace arrancar la bomba 2 La bomba seguir funcionando hasta que el nivel de l qu...

Page 19: ...pulg ESTACI N DE BOMBA SIMPLE sistema de 3 flotadores Bomba apagada Nivel hasta la parte superior del chasis Bomba encendida M nimo 45 72 cm 1 5 pies por arriba del nivel de la bomba apagada Alarma de...

Page 20: ...MENTE NO CAMBIE LOS HILOS DE ALIMENTACI N NO ENCIENDA LA BOMBA COMPRUEBE SIEMPRE QUE NO HAYA CABLES SUELTOS Y OTRAS OBSTRUCCIONES QUE PUDIERAN CAUSAR LESIONES PERSONALES O DESPERFECTOS MANTENIMIENTO Y...

Page 21: ...edado cerrada o est instalada al rev s Saque la v lvula de retenci n y aseg rese de que funciona sin impedimentos y que haya sido instalada correctamente La v lvula de compuerta o la de bola est cerra...

Page 22: ...instalado correctamente si ha sido desmontado modificado abusado o forzado si el cable el ctrico se ha cortado da ado o empalmado si se redujo el tama o de la descarga de la bomba si la bomba se us co...

Page 23: ...230V monophas e cordon d alimentation de 3 m 10 pi PRG102M 2 1 hp 230V monophas e cordon d alimentation de 3 m 25 pi Ne pas jeter ni perdre ce manuel Table des mati res Renseignements g n raux Introd...

Page 24: ...tuyauterie ayant d j servi Ne jamais p n trer dans le r servoir de pompage apr s qu il ait servi Les gouts et effluents peuvent mettre des gaz toxiques Demeurer l cart des orifices d aspiration et d...

Page 25: ...h it m canique comportant deux c t s en carbure de silicium 4 Le compresseur et la sortie sont con us pour une utilisation sans obstruction et comportent des caract ristiques d coulement efficaces Les...

Page 26: ...iberty Pumps en cas de doute au sujet de la taille du bassin qui convient L installation doit tre suffisamment profonde pour assurer que toute la plomberie se trouve sous la profondeur maximale de la...

Page 27: ...rrectement mis la terre ou s il est muni d une fiche avec mise la terre qu elle est correctement mise la terre NE PAS d vier les fils de mise la terre ou retirer les broches de mise la terre des fiche...

Page 28: ...n minimum de 8 9 cm 3 5 po entre le point d attache et le haut du flotteur est n cessaire au bon fonctionnement de l interrupteur Lorsqu on utilise un intervalle diff rent de celui qui est r gl en usi...

Page 29: ...sure que le niveau de liquide monte dans la b che d aspiration le flotteur bascule et ferme l interrupteur Cela fait d marrer la pompe 2 La pompe tourne jusqu ce que le niveau de liquide descende au n...

Page 30: ...ngle de 3 5 po STATION DE POMPAGE SIMPLE Syst me 3 flotteurs Pompe arr t e niveau du sommet du bo tier du moteur Pompe en marche au moins 46 cm 1 pi au dessus du niveau de pompe arr t e Alarme de nive...

Page 31: ...NVERSER LES BORNES D ALIMENTATION LECTRIQUE NE PAS FAIRE FONCTIONNER LA POMPE TOUJOURS S ASSURER QUE LA POMPE EST LIBRE DE TOUTE OBSTRUCTION PAR DES C BLES OU AUTRES L MENTS POUVANT PROVOQUER DES DOMM...

Page 32: ...lisation d vacuation se trouve dans des zones froides ou les traverse Clapet antiretour bloqu en position ferm e ou incorrectement install Retirer tout clapet antiretour et v rifier qu il fonctionne l...

Page 33: ...usage abusif ou endommag si le cordon lectrique a t coup endommag ou ligatur si la taille du tuyau d vacuation de la pompe a t r duite si la pompe a t utilis e pour pomper de l eau d une temp rature...

Reviews: