Liberty Pumps ProVore PRG101A Installation Manual Download Page 2

 

      ©Copyright 2013 Liberty Pumps Inc.    All rights reserved  

- 2 - 

1.  

 

General Information       

 X

  

 

 

 

Before  installation,  read  the  following  instructions  carefully.    Each  Liberty  pump  is  individually  factory  tested  to  insure  proper 

performance.    Closely  following  these  instructions  will  eliminate  potential  operating  problems,  assuring  years  of  trouble-free 

service. 

 

 

 

 

Risk  of  electric  shock

.    Always  disconnect  the  pump  from  the  power  source  before  handling  or  making 

adjustments.   

 

The electrical connections and wiring for a pump installation should only be made by qualified personnel. 

 

This pump is supplied with a grounding conductor and grounding-type attachment plug.  To reduce the risk of 

electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.   

 

DO NOT bypass grounding wires or remove ground prong from attachment plugs. 

 

DO NOT use an extension cord.  

 

This pump requires a separate, properly fused and grounded branch circuit.  Make sure the power source is 

properly sized for the voltage and amperage requirements of the pump, as noted on the nameplate. 

 

The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor 

level to minimize possible hazards from flood conditions.  

 

The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International 

Plumbing Code, as well as all applicable local codes and ordinances. 

 

Sump and sewage pumps often handle materials which could cause illness or disease.  Wear adequate protective 

clothing when working on a used pump or piping. 

 

Never enter a pump basin after it has been used.  Sewage and effluent can emit several gases which are 

poisonous. 

 

Keep clear of suction and discharge openings.  To prevent injury, never insert fingers into pump while it is 

plugged in. 

 

DO NOT use this product for flammable or corrosive liquid.   

 

DO  NOT  use  this  product  in  applications  where  human  contact  with  the  pumped  fluid  is  common  (such  as 

swimming pools, fountains, etc.) 

 

NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack 

and damage pump components, potentially causing product malfunction or failure. 

 

DO NOT run pump dry, this product is intended to be partway submerged when operating. 

 

 

 

Do not use these pumps in water over 140

 F. 

 

The Uniform Plumbing Code (UPC) states that sewage systems shall have an audio and visual alarm that signals 

a malfunction of the system, to reduce the potential for property damage. 

 

 

A 20 amp breaker is recommended for 115V pumps. 

 

 

 

Note:

    Manual  models  (“M” 

suffix),  require  a  separate 

approved pump control device or 

panel  for  automatic  operation.  

Operation of these models will be 

according to the control selected.  

Make 

sure 

the 

electrical 

specifications  of  the  control 

selected  properly  match  the 

electrical  specifications  of  the 

pump.    Always  refer  to  control 

panel  instructions  for  proper 

installation. 

 

 

 

 

 

 

Model 

HP 

Volts 

Phase 

Full 

Load 

Amps 

FNPT 

Discharge 

Automatic or 

Manual* 

PRG101A 

115 

12 

2” 

Automatic 

PRG101A-2 

115 

12 

2” 

Automatic 

PRG101M 

115 

12 

2” 

Manual 

PRG101M-2 

115 

12 

2” 

Manual 

 

 

 

 

 

 

 

PRG102A 

230 

2” 

Automatic 

PRG102A-2 

230 

2” 

Automatic 

PRG102M 

230 

2” 

Manual 

PRG102M-2 

230 

2” 

Manual 

Summary of Contents for ProVore PRG101A

Page 1: ...r cord PRG102M 2 1 hp 230V 1 phase 25 Power cord Do not throw away or lose this manual Contents General Information Introduction Mechanical Installation Electrical Connection Operation Troubleshooting...

Page 2: ...adequate protective clothing when working on a used pump or piping Never enter a pump basin after it has been used Sewage and effluent can emit several gases which are poisonous Keep clear of suction...

Page 3: ...l type cartridge seal with two silicon carbide faces 4 The impeller and volute are designed for efficient flow characteristics and clog free operation The hardened cutters grind solids and fibrous mat...

Page 4: ...ending on local codes and the number of fixture units entering the system Check with the local authorities or contact Liberty Pumps if you are unsure of the proper basin size Installation should be at...

Page 5: ...ent plug To reduce the risk of electric shock be certain that the grounding conductor is connected only to a properly grounded control panel or if equipped with a grounding type plug that it is connec...

Page 6: ...switch cord to the discharge pipe NOTE A minimum cord length of 3 5 from the tether point to the top surface of the float is required for proper switch operation If using a differential other than th...

Page 7: ...Refer to panel or switch instructions for proper electrical connection FLOAT SEQUENCE PIGGY BACK SWITCH AUTOMATIC MODELS 1 As the liquid level in the wet well rises the float tilts closing the switch...

Page 8: ...ump Off Factory set Float tether 3 5 Pump On Factory set Float tether 3 5 SIMPLEX PUMP STATION 3 Float System Pump Off Level to top of motor housing Pump On Minimum 1 1 2 ft above Pump Off Level High...

Page 9: ...IFY THE LIBERTY PRODUCT SERVICE DEPARTMENT IMMEDIATELY DO NOT SWITCH THE POWER SUPPLY LEADS DO NOT OPERATE THE PUMP ALWAYS ENSURE THAT THE PUMP IS FREE OF WIRES OR OTHER OBSTRUCTIONS THAT MAY CAUSE HA...

Page 10: ...ischarge line passes through or into cold areas Check valve is stuck closed or installed backwards Remove check valve s and examine for freedom of operation and proper installation Gate or ball valve...

Page 11: ...installed if it has been disassembled modified abused or tampered with if the electrical cord has been cut damaged or spliced if the pump discharge has been reduced in size if the pump has been used i...

Page 12: ...sica cord n el ctrico de 10 pies 3 m PRG102M 2 1 hp 230 V monof sica cord n el ctrico de 25 pies 8 3 m No tire ni pierda este manual Manual de instalaci n 2399000B Bombas trituradoras residenciales Pr...

Page 13: ...grese a una cubeta de bomba despu s que haya sido usada Los sistemas de efluentes y de alcantarillado pueden emitir diferentes tipos de gases t xicos Mant ngase alejado de la entrada de succi n y de l...

Page 14: ...de carburo de silicio 4 El rotor y la voluta est n dise ados para producir un caudal ptimo y funcionar sin obstrucciones Los discos endurecidos trituran la materia s lida y fibrosa hasta convertirla...

Page 15: ...undidad suficiente como para que todas las ca er as queden por debajo de la l nea de penetraci n de la helada Si esto no fuera posible desmonte la v lvula de retenci n y modifique el tama o de la cube...

Page 16: ...conectado debidamente a un panel de control a tierra o si cuenta con un enchufe a tierra tendr que enchufarse a un tomacorriente conectado a tierra NO derive los cables de puesta a tierra ni retire l...

Page 17: ...lotador para que el interruptor funcione correctamente Si se va a utilizar un diferencial distinto al de f brica se deber ajustar de forma que la bomba se apague cuando queden 15 24 cm 6 pulg como m n...

Page 18: ...OS 1 El flotador se va inclinando a medida que sube el nivel del sumidero inundado con lo que cierra el interruptor Esto hace arrancar la bomba 2 La bomba seguir funcionando hasta que el nivel de l qu...

Page 19: ...pulg ESTACI N DE BOMBA SIMPLE sistema de 3 flotadores Bomba apagada Nivel hasta la parte superior del chasis Bomba encendida M nimo 45 72 cm 1 5 pies por arriba del nivel de la bomba apagada Alarma de...

Page 20: ...MENTE NO CAMBIE LOS HILOS DE ALIMENTACI N NO ENCIENDA LA BOMBA COMPRUEBE SIEMPRE QUE NO HAYA CABLES SUELTOS Y OTRAS OBSTRUCCIONES QUE PUDIERAN CAUSAR LESIONES PERSONALES O DESPERFECTOS MANTENIMIENTO Y...

Page 21: ...edado cerrada o est instalada al rev s Saque la v lvula de retenci n y aseg rese de que funciona sin impedimentos y que haya sido instalada correctamente La v lvula de compuerta o la de bola est cerra...

Page 22: ...instalado correctamente si ha sido desmontado modificado abusado o forzado si el cable el ctrico se ha cortado da ado o empalmado si se redujo el tama o de la descarga de la bomba si la bomba se us co...

Page 23: ...230V monophas e cordon d alimentation de 3 m 10 pi PRG102M 2 1 hp 230V monophas e cordon d alimentation de 3 m 25 pi Ne pas jeter ni perdre ce manuel Table des mati res Renseignements g n raux Introd...

Page 24: ...tuyauterie ayant d j servi Ne jamais p n trer dans le r servoir de pompage apr s qu il ait servi Les gouts et effluents peuvent mettre des gaz toxiques Demeurer l cart des orifices d aspiration et d...

Page 25: ...h it m canique comportant deux c t s en carbure de silicium 4 Le compresseur et la sortie sont con us pour une utilisation sans obstruction et comportent des caract ristiques d coulement efficaces Les...

Page 26: ...iberty Pumps en cas de doute au sujet de la taille du bassin qui convient L installation doit tre suffisamment profonde pour assurer que toute la plomberie se trouve sous la profondeur maximale de la...

Page 27: ...rrectement mis la terre ou s il est muni d une fiche avec mise la terre qu elle est correctement mise la terre NE PAS d vier les fils de mise la terre ou retirer les broches de mise la terre des fiche...

Page 28: ...n minimum de 8 9 cm 3 5 po entre le point d attache et le haut du flotteur est n cessaire au bon fonctionnement de l interrupteur Lorsqu on utilise un intervalle diff rent de celui qui est r gl en usi...

Page 29: ...sure que le niveau de liquide monte dans la b che d aspiration le flotteur bascule et ferme l interrupteur Cela fait d marrer la pompe 2 La pompe tourne jusqu ce que le niveau de liquide descende au n...

Page 30: ...ngle de 3 5 po STATION DE POMPAGE SIMPLE Syst me 3 flotteurs Pompe arr t e niveau du sommet du bo tier du moteur Pompe en marche au moins 46 cm 1 pi au dessus du niveau de pompe arr t e Alarme de nive...

Page 31: ...NVERSER LES BORNES D ALIMENTATION LECTRIQUE NE PAS FAIRE FONCTIONNER LA POMPE TOUJOURS S ASSURER QUE LA POMPE EST LIBRE DE TOUTE OBSTRUCTION PAR DES C BLES OU AUTRES L MENTS POUVANT PROVOQUER DES DOMM...

Page 32: ...lisation d vacuation se trouve dans des zones froides ou les traverse Clapet antiretour bloqu en position ferm e ou incorrectement install Retirer tout clapet antiretour et v rifier qu il fonctionne l...

Page 33: ...usage abusif ou endommag si le cordon lectrique a t coup endommag ou ligatur si la taille du tuyau d vacuation de la pompe a t r duite si la pompe a t utilis e pour pomper de l eau d une temp rature...

Reviews: