Unison Component Installation Procedures
7-32
InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620003-0-20 Rev J
The System Configuration window appears.
9.
Select the operating band from the Select Band pull down menu.
The operating band must match the band of the RAUs that are used in the system.
10.
Change the System Gain in the text boxes, if desired.
The default is 0 dB for both the uplink and downlink.
11.
Change the System Label, if desired.
The default is “Unison.”
12.
Click
OK
.
During configuration, which can take several minutes for a fully-loaded system
(that is, 32 RAUs), all disconnect status are cleared; the frequency band, gain, and
system label are set; logs are cleared; the system test is performed; and finally the
status tree is refreshed. The icons should be:
Indicating that the band is correctly set.
Indicating that communications are OK.
Indicating that communications are OK.
If there are problems, the icons are different and a message is displayed in the
Messages pane.
The Unison system should now be operational. Using a mobile phone, walk your
site and test the signal strength.
NOTE:
Refer to Section 9 for troubleshooting.