Unison Component Installation Procedures
7-28
InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620003-0-20 Rev J
Figure 7-5
Dual Band RAU Configuration
To connect the RAUs and Dual Band Diplexer for a dual band system:
Unison
RAU
Unison
RAU
Dual Band
Diplexer
Cat-5E/6 from Expansion Hub
Cat-5E/6 from Expansion Hub
Antenna
3 ft. coaxial cable
3 ft. coaxial cable
Dual Band Diplexer
1.
Verify that the Unison system is powered on.
2.
Attach the Diplexer to a stable surface (that
is, wall, ceiling tile, pole).
Do not mount the Diplexer on top of an RAU.
3.
Attach the two RAUs to a stable surface
within 2.5 ft. of the Diplexer (do not stack the RAUs on top of each other).
4.
Connect the Cat-5E/6 cable coming from the Unison lower band system (that is,
system band below 1 GHZ) to the correct RAU.
The
LINK
LED on the RAU should be green.
5.
Connect the Cat-5E/6 cable coming from the Unison upper band system (that is,
system band above 1 GHZ) to the correct RAU.
The
LINK
LED on the RAU should be green.
6.
Connect a coaxial cable to the antenna ports on each of the RAUs.
The recommended coaxial cable (PN 4005-3) is 3 ft. long.
7.
Connect the coaxial cable coming from the Unison lower band system (that is,
system band below 1 GHZ) to the Diplexer port labeled “LOWER BAND.”
8.
Connect the coaxial cable coming from the Unison upper band system (that is,
system band above 1 GHZ) to the Diplexer port labeled “UPPER BAND.”
9.
Connect a coaxial cable from the dual band antenna to the Diplexer port labeled
“ANTENNA.”