Help Hot Line (U.S. only): 1-800-530-9960
7-3
D-620003-0-20 Rev J
CONFIDENTIAL
Installation Requirements
Table 7-1
Unison Distance Requirements
Equipment
Combination
Cable Type
Distance
Additional Information
Repeater to Main
Hub
Coaxial; N male
connectors
3–6 m (10–20 ft) typical
Limited by loss and noise.
Refer to your link budget
calculation.
10 m (33 ft) maximum
Limited by CE Mark require-
ments.
Base Station to Main
Hub
Coaxial; N male
connectors
3–6 m (10–20 ft) typical
Limited by loss and noise.
Refer to your link budget
calculation.
10 m (33 ft) maximum
Limited by CE Mark require-
ments.
Main Hub to
Expansion Hub
Multi-mode Fiber:
Single-mode Fiber:
SC/APC male
connectors
1.5 km (4,921 ft) max.
6 km (19,685 ft) max.
Limited by 3 dB optical loss.
Expansion Hub to
RAU
Cat-5E/6 ScTP;
shielded RJ-45 male
connectors
• Minimum: 10 meters (33 ft)
• Recommended Max.: 100 meters (328 ft)
See Section 7.4.5 if using a Cat-5 Extender
Refer to “System Gain (Loss)
Relative to ScTP Cable
Length” on page 6-23.
RAU to passive
antenna
Coaxial; SMA male
connectors
1–3.5 m (3–12 ft) typical
Limited by loss and noise.
Refer to your link budget
calculation.