124
INSTALLER SETTING
ENGLISH
In this mode, setting temperature will follow outdoor temperature automatically. This mode adds
the cooling season function to the conventional weather dependent operation mode.
Auto-Adjustable
Target Temp.
Room Air
Temp.(°C)
Leaving
Water Temp.
Outdoor
Air Temp.
Heating
Set point 1
30~20
57~39
Set point 5
-20 ~ -10
Set point 2
19~16
38~20
Set point 6
-5 ~ 5
Cooling
Set point 3
30~24
25~17
Set point 7
10 ~ 18
Set point 4
23~18
16~6
Set point 8
22 ~ 30
Auto-Adjustable
Target Temperature
Set point 1
Set point 2
Set point 3
Set point 4
Set point 5
Set point 6
Set point 7
Set point 8
Outdoor
air temperature
Temperature profile
of weather dependent operation
Heating
Cooling
o