123
INSTALLER SETTING
ENGLISH
OK
Seasonal auto temp
It is the function to set the operation reference value in Seasonal Auto mode.
• In the installer setting list, select Seasonal auto temp category, and press [OK] button to move
to the detail screen.
- Setting range: Celsius
- Seasonal Auto Driving mode: Heating, Heating & Cooling, Air-conditioning
* If heating mode is selected, heating & cooling or cooling can not be selected.
- Depending on the air / outflow control selection value, the water / air related setting value is
displayed on the screen.
Function
Description
Range
Default
Boundary
Outdoor1,Heat
(Out1)
Heating lower ambient temp
-25~35 °C
-10°C
Out1
←
Out2-1
Outdoor2,Heat
(Out2)
Heating higher ambient temp
16°C
Out2
→
Out1 +1
Out2
←
Out3 -5
Outdoor3,Cool
(Out3)
Cooling lower ambient temp
10~46°C
30°C
Out3
→
Out2 +5
Out3
←
Out4 -1
Tank setting 2
Setting maintain temperature
for operation
40°C
Out4
→
Out3 +1
Water1,Heat
(LW1)
Heating higher water temp
Use heater :
LW STD : 15~65°C
EW STD : 15~55°C
Not use heater :
LW STD : 20~65°C
EW STD : 20~55°C
35°C
LW1
←
LW2
DHW time
setting
Determine follow time
duration : operation time of
domestic hot water tank
heating, stop time of domestic
hot water tank heating, and
delay time of DHW tank heater
operating
28°C
LW1
←
LW2
Water3,Cool
(LW3)
Cooling higher water temp
Use FCU & 5°C IDU :
LW STD : 5~27°C
EW STD : 10~27°C
Use FCU & 6°C IDU :
LW STD : 6~27°C
EW STD : 11~27°C
Not use FCU :
LW STD : 16~27°C
EW STD : 20~27°C
20°C
LW3
←
LW4
Water4,Cool
(LW4)
Cooling lower water temp
16°C
LW3
←
LW4