118
INSTALLER SETTING
ENGLISH
Pump setting. in cooling
• It is a function to help the water pump's mechanical life by putting the water pump's rest time
• installer setting function to set water pump operation / delay time option in cooling mode
• In the installer setting list, select Pump setting in cooling category, and press [OK] button to
move to the detail screen.
OK
Type
Time setting
Operation continue
On
1 min ~ 60 min
-
Off
1 min ~ 60 min
-