Table 298:
LMU540HV Cooling Capacity Table — Mixed Indoor Units (continued).
PERFORMANCE DATA
Cooling Capacity Tables
Combination
Capacity Index
(kBtu/h[%])
Outdoor Air
Temp.
(°F DB)
Indoor Air Temp. °F DB / °F WB
68 / 57
73 / 61
77 / 64
80 / 67
86 / 72
90 / 75
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
Mixed Indoor
Units
54 (100%)
14
50.73
3.19
53.88
3.31
57.03
3.43
59.31
3.47
63.33
3.53
66.48
3.60
20
50.69
3.24
53.84
3.36
56.99
3.48
59.26
3.52
63.28
3.58
66.43
3.66
25
50.65
3.28
53.80
3.40
56.94
3.53
59.22
3.57
63.24
3.63
66.38
3.71
30
50.61
3.33
53.76
3.45
56.90
3.58
59.17
3.62
63.19
3.69
66.33
3.76
35
50.58
3.38
53.72
3.50
56.86
3.63
59.13
3.67
63.14
3.74
66.28
3.81
40
50.54
3.42
53.68
3.55
56.81
3.68
59.08
3.72
63.09
3.79
66.23
3.86
45
50.50
3.47
53.63
3.59
56.77
3.72
59.04
3.77
63.04
3.84
66.18
3.92
50
50.46
3.51
53.59
3.64
56.73
3.77
58.99
3.82
62.99
3.89
66.13
3.97
55
50.42
3.56
53.55
3.69
56.68
3.82
58.95
3.87
62.95
3.94
66.08
4.02
60
50.38
3.60
53.51
3.74
56.64
3.87
58.90
3.92
62.90
3.99
66.03
4.07
65
50.34
3.65
53.47
3.78
56.60
3.92
58.85
3.97
62.85
4.04
65.98
4.12
70
50.30
3.70
53.43
3.83
56.55
3.97
58.81
4.02
62.80
4.09
65.93
4.17
75
49.09
3.90
52.21
4.04
55.33
4.19
57.58
4.23
61.56
4.31
64.68
4.40
80
47.88
4.09
50.99
4.24
54.10
4.40
56.35
4.45
60.32
4.53
63.43
4.62
85
46.68
4.29
49.78
4.45
52.89
4.61
55.13
4.67
59.09
4.75
62.19
4.85
90
45.48
4.49
48.58
4.66
51.67
4.83
53.90
4.88
57.86
4.97
60.95
5.07
95
44.18
4.69
47.26
4.86
50.34
5.04
51.75
5.10
56.49
5.20
59.57
5.30
100
43.11
4.89
46.18
5.07
49.26
5.26
51.08
5.32
55.42
5.42
58.50
5.53
105
42.03
5.09
45.11
5.28
48.19
5.47
50.41
5.53
54.34
5.64
57.42
5.75
110
40.95
5.29
44.03
5.48
47.11
5.68
49.33
5.75
53.27
5.86
56.34
5.98
115
39.88
5.49
42.96
5.69
46.03
5.90
48.26
5.97
52.19
6.08
55.27
6.20
118
39.23
5.61
42.31
5.82
45.39
6.03
47.61
6.10
51.54
6.21
54.62
6.34
122
39.02
5.77
42.10
5.98
45.17
6.20
47.40
6.27
51.33
6.39
54.41
6.52
Mixed Indoor
Units
49 (90%)
14
46.03
2.82
48.89
2.93
51.75
3.03
53.82
3.07
57.47
3.12
60.33
3.19
20
46.00
2.86
48.86
2.97
51.71
3.08
53.78
3.11
57.43
3.17
60.28
3.23
25
45.96
2.90
48.82
3.01
51.67
3.12
53.74
3.16
57.38
3.21
60.24
3.28
30
45.93
2.94
48.78
3.05
51.63
3.16
53.69
3.20
57.34
3.26
60.19
3.32
35
45.89
2.98
48.74
3.09
51.59
3.21
53.65
3.24
57.30
3.30
60.15
3.37
40
45.86
3.03
48.71
3.14
51.56
3.25
53.61
3.29
57.25
3.35
60.10
3.42
45
45.82
3.07
48.67
3.18
51.52
3.29
53.57
3.33
57.21
3.39
60.05
3.46
50
45.79
3.11
48.63
3.22
51.48
3.34
53.53
3.38
57.16
3.44
60.01
3.51
55
45.75
3.15
48.60
3.26
51.44
3.38
53.49
3.42
57.12
3.48
59.96
3.55
60
45.72
3.19
48.56
3.30
51.40
3.42
53.45
3.46
57.08
3.53
59.92
3.60
65
45.68
3.23
48.52
3.35
51.36
3.47
53.41
3.51
57.03
3.57
59.87
3.65
70
45.65
3.27
48.48
3.39
51.32
3.51
53.37
3.55
56.99
3.62
59.82
3.69
75
44.55
3.44
47.38
3.57
50.21
3.70
52.25
3.74
55.86
3.81
58.69
3.89
80
43.45
3.62
46.27
3.75
49.09
3.89
51.13
3.94
54.74
4.01
57.56
4.09
85
42.36
3.80
45.18
3.94
47.99
4.08
50.02
4.13
53.62
4.20
56.43
4.29
90
41.27
3.97
44.08
4.12
46.89
4.27
48.92
4.32
52.50
4.40
55.31
4.49
95
40.09
4.15
42.89
4.30
45.68
4.46
46.96
4.51
51.26
4.59
54.06
4.69
100
39.12
4.33
41.91
4.48
44.70
4.65
46.35
4.70
50.29
4.79
53.08
4.89
105
38.14
4.50
40.93
4.67
43.73
4.84
45.74
4.89
49.31
4.98
52.11
5.09
110
37.16
4.68
39.96
4.85
42.75
5.03
44.77
5.08
48.34
5.18
51.13
5.28
115
36.19
4.86
38.98
5.03
41.77
5.22
43.79
5.28
47.36
5.38
50.15
5.48
118
35.60
4.96
38.39
5.14
41.19
5.33
43.20
5.39
46.77
5.49
49.57
5.60
122
35.41
5.10
38.20
5.29
40.99
5.48
43.01
5.54
46.58
5.65
49.37
5.76
TC = Total Capacity (kBtu/h).
PI = Power Input (kW).
Nominal capacity as rated: 0 ft. above sea level with Piping Length as Main Pipe (16.4 ft.) + Branch
pipe (98.4 ft.) = 115 ft.
0 ft. level difference between outdoor and indoor units.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and
67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
The shaded table columns and rows indicate reference data. When operating at this temperature, these
values can be different if the system is not running consistently.
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
312 | MULTI F MAX OUTDOOR UNIT
Multi F and Multi F MAX Heat Pump System Engineering Manual