MULTI F OUTDOOR UNIT | 127
Multi F Outdoor Unit Data
Due to our policy of continuous product innovation, some specifications may change without notification.
©
LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
MULTI
F
MAX
MULTI
F
PERFORMANCE DATA
Cooling Capacity Tables
Connected Indoor
Units
Combination
Capacity
Index
Outdoor Air
Temp. (°F
DB)
Indoor Air Temp. °F DB / °F WB
68 / 57
73 / 61
77 / 64
80 / 67
86 / 72
90 / 75
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
TC
PI
Two (2) Ducted
Indoor Units
9 + 9
14
15.44
1.11
16.40
1.15
17.36
1.20
18.05
1.21
19.28
1.23
20.23
1.26
20
15.43
1.13
16.39
1.17
17.34
1.21
18.04
1.23
19.26
1.25
20.22
1.28
25
15.42
1.15
16.37
1.19
17.33
1.23
18.02
1.24
19.25
1.27
20.20
1.29
30
15.40
1.16
16.36
1.20
17.32
1.25
18.01
1.26
19.23
1.29
20.19
1.31
35
15.39
1.18
16.35
1.22
17.30
1.26
17.99
1.28
19.22
1.30
20.17
1.33
40
15.38
1.19
16.34
1.24
17.29
1.28
17.98
1.30
19.20
1.32
20.16
1.35
45
15.37
1.21
16.32
1.25
17.28
1.30
17.97
1.31
19.19
1.34
20.14
1.37
50
15.36
1.23
16.31
1.27
17.26
1.32
17.95
1.33
19.17
1.36
20.13
1.38
55
15.35
1.24
16.30
1.29
17.25
1.33
17.94
1.35
19.16
1.37
20.11
1.40
60
15.33
1.26
16.29
1.30
17.24
1.35
17.93
1.37
19.14
1.39
20.10
1.42
65
15.32
1.27
16.27
1.32
17.23
1.37
17.91
1.38
19.13
1.41
20.08
1.44
70
15.31
1.29
16.26
1.34
17.21
1.39
17.90
1.40
19.11
1.43
20.06
1.46
75
14.94
1.36
15.89
1.41
16.84
1.46
17.52
1.48
18.74
1.50
19.68
1.53
80
14.57
1.43
15.52
1.48
16.47
1.53
17.15
1.55
18.36
1.58
19.30
1.61
85
14.21
1.50
15.15
1.55
16.10
1.61
16.78
1.63
17.98
1.66
18.93
1.69
90
13.84
1.57
14.78
1.62
15.73
1.68
16.41
1.70
17.61
1.74
18.55
1.77
95
13.45
1.64
14.38
1.70
15.32
1.76
15.75
1.78
17.19
1.81
18.13
1.85
100
13.12
1.71
14.06
1.77
14.99
1.83
15.55
1.85
16.87
1.89
17.80
1.93
105
12.79
1.78
13.73
1.84
14.67
1.91
15.34
1.93
16.54
1.97
17.48
2.01
110
12.46
1.85
13.40
1.91
14.34
1.98
15.01
2.01
16.21
2.04
17.15
2.08
115
12.14
1.92
13.07
1.99
14.01
2.06
14.69
2.08
15.88
2.12
16.82
2.16
118
11.94
1.96
12.88
2.03
13.81
2.10
14.49
2.13
15.69
2.17
16.62
2.21
122
11.87
2.01
12.81
2.09
13.75
2.16
14.43
2.19
15.62
2.23
16.56
2.27
9 + 12
14
18.01
1.28
19.13
1.32
20.25
1.37
21.06
1.39
22.49
1.41
23.61
1.44
20
18.00
1.29
19.12
1.34
20.23
1.39
21.04
1.41
22.47
1.43
23.59
1.46
25
17.99
1.31
19.10
1.36
20.22
1.41
21.03
1.43
22.45
1.45
23.57
1.48
30
17.97
1.33
19.09
1.38
20.20
1.43
21.01
1.45
22.44
1.47
23.55
1.50
35
17.96
1.35
19.07
1.40
20.19
1.45
20.99
1.47
22.42
1.49
23.53
1.52
40
17.94
1.37
19.06
1.42
20.17
1.47
20.98
1.49
22.40
1.51
23.52
1.54
45
17.93
1.39
19.04
1.44
20.16
1.49
20.96
1.51
22.38
1.53
23.50
1.56
50
17.92
1.40
19.03
1.45
20.14
1.51
20.95
1.53
22.37
1.55
23.48
1.58
55
17.90
1.42
19.01
1.47
20.13
1.53
20.93
1.55
22.35
1.57
23.46
1.61
60
17.89
1.44
19.00
1.49
20.11
1.55
20.91
1.56
22.33
1.59
23.44
1.63
65
17.88
1.46
18.99
1.51
20.10
1.57
20.90
1.58
22.32
1.61
23.43
1.65
70
17.86
1.48
18.97
1.53
20.08
1.59
20.88
1.60
22.30
1.63
23.41
1.67
75
17.43
1.56
18.54
1.61
19.65
1.67
20.44
1.69
21.86
1.72
22.96
1.76
80
17.00
1.64
18.11
1.70
19.21
1.76
20.01
1.78
21.42
1.81
22.52
1.85
85
16.58
1.72
17.68
1.78
18.78
1.84
19.57
1.86
20.98
1.90
22.08
1.94
90
16.15
1.80
17.25
1.86
18.35
1.93
19.14
1.95
20.54
1.99
21.64
2.03
95
15.69
1.87
16.78
1.94
17.87
2.01
18.38
2.04
20.06
2.08
21.15
2.12
100
15.31
1.95
16.40
2.03
17.49
2.10
18.14
2.12
19.68
2.16
20.77
2.21
105
14.92
2.03
16.02
2.11
17.11
2.19
17.90
2.21
19.30
2.25
20.39
2.30
110
14.54
2.11
15.63
2.19
16.73
2.27
17.52
2.30
18.91
2.34
20.01
2.39
115
14.16
2.19
15.25
2.27
16.35
2.36
17.13
2.38
18.53
2.43
19.62
2.48
118
13.93
2.24
15.02
2.32
16.12
2.41
16.91
2.44
18.30
2.48
19.40
2.53
122
13.85
2.31
14.95
2.39
16.04
2.48
16.83
2.51
18.23
2.55
19.32
2.60
Table 120:
LMU36CHV Cooling Capacity Table — Ducted Indoor Units
TC = Total Capacity (kBtu/h).
PI = Power Input (kW).
Nominal capacity as rated: 0 ft. above sea level with 25 ft. of refrigerant piping.
0 ft. level difference between outdoor and indoor units.
Nominal cooling capacity rating obtained with air entering the indoor unit at 80ºF dry bulb (DB) and
67ºF wet bulb (WB), and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
The shaded table rows indicate reference data. When operating at this temperature, these values can
be different if the system is not running consistently.